Gorman-Rupp Pumps 82E52-B 1327232 and up User Manual

Page 26

Advertising
background image

OM−00825

80 SERIES

MAINTENANCE & REPAIR

PAGE E − 5

Pump Casing and Wear Plate Removal

To service the impeller (2), wear plate assembly
(21) and seal assembly (3), disconnect the dis-
charge piping. Remove the hardware securing the
pump casing (1) to the base.

Remove the nuts (40) securing the pump casing
and gasket set (19) to the pedestal (14) and seal
plate (18). Install a standard 5/8−11 UNC lifting
eye in the tapped hole in the top of the pump cas-
ing. Be sure to screw the eye into the casing until
fully engaged. Use a hoist and sling of suitable ca-
pacity to separate the casing from the seal plate
and pedestal.

Do not attempt to lift the complete pump
unit using the lifting eye. It is designed
to facilitate removal or installation of in-
dividual components only. Additional
weight may result in damage to the
pump or failure of the eye bolt.

Remove the gasket set from the pedestal and seal
plate. Tie and tag the gaskets, or measure and re-
cord their thickness for ease of reassembly. Tie and
tag any leveling shims used under the casing
mounting feet to ease reassembly.

Inspect the wear plate assembly and replace it if
badly scored or worn. To remove the wear plate as-
sembly, remove the capscrew (25) and fiber wash-
er (26) just below the suction port. Reach through
the suction port and disengage the hardware (37
and 38) from the wear plate stud. Tap the wear
plate assembly free of the casing.

Impeller Removal

Immobilize the impeller by wedging a block of
wood between the vanes. If removed, install the
shaft key (8). Install a lathe dog on the drive end of
the shaft (9) with the V" notch positioned over the
shaft keyway. Remove the hardware (20, 22 and
23) securing the impeller to the shaft.

With the impeller rotation still blocked, usE a long
piece of heavy bar stock to pry against the arm of
the lathe dog in a counterclockwise direction
(when facing the drive end of the shaft) as shown in
Figure 2. Use caution not to damage the shaft or

keyway. When the impeller breaks loose, remove
the lathe dog and wood block and unscrew the im-
peller from the shaft.

Turn

Counterclockwise

Lathe Dog Arm

V" Notch

Shaft Key

Impeller Shaft

Lathe Dog

Setscrew

Heavy

Bar Stock

Figure 2. Loosening Impeller

Unscrew the impeller from the shaft. Use caution
when removing the impeller; tension on the seal
spring will be released as the impeller is un-
screwed.

Inspect the impeller and replace it if cracked or
badly worn. Slide the impeller adjusting shims (48)
off the impeller shaft. Tie and tag the shims, or
measure and record their thickness for ease of
reassembly.

Seal Removal

(Figures 1 or 3)

Remove the spring seat (47) and seal spring. Care-
fully slide the shaft sleeve (46), and rotating portion
of the seal off the shaft (9) as a unit. Apply oil to the
sleeve and work it up under the rubber bellows.
Slide the rotating portion of the seal off the sleeve.

Carefully slide the seal plate and stationary portion
of the seal off the shaft as a unit. Lay the seal plate
on a clean, flat surface with the impeller side down
and use a suitably sized dowel to press the station-
ary seat and O-ring out of the seal plate from the
back side.

If no further disassembly is required, see Seal
Reassembly and Installation.

Shaft And Bearing Removal And Disassembly

When the pump is properly operated and main-
tained, the pedestal should not require disassem-

Advertising