Gorman-Rupp Pumps 82H3-B 716123 and up User Manual

Page 23

Advertising
background image

OM−00831

80 SERIES

MAINTENANCE & REPAIR

PAGE E − 4

PUMP AND SEAL DISASSEMBLY
AND REASSEMBLY

Review all SAFETY information in Section A.

Follow the instructions on all tags, label and de-
cals attached to the pump.

This pump requires little service due to its rugged,
minimum-maintenance design. However, if it be-
comes necessary to inspect or replace the wearing
parts, follow these instructions which are keyed to
the sectional view (see Figure 1) and the accompa-
nying parts lists.

As described on the following pages, this manual
will alert personnel to known procedures which re-
quire special attention, to those which could dam-
age equipment, and to those which could be dan-
gerous to personnel. However, this manual cannot
possibly anticipate and provide detailed precau-
tions for every situation that might occur during
maintenance of the unit. Therefore, it is the respon-
sibility of the owner/maintenance personnel to en-
sure that only safe, established maintenance pro-
cedures are used, and that any procedures not ad-
dressed in this manual are performed only after es-
tablishing that neither personal safety nor pump in-
tegrity are compromised by such practices.

Before attempting to service the pump, lock out or
disconnect the power source to ensure that it will
remain inoperative. Close all valves in the suction
and discharge lines.

For power source disassembly and repair, consult
the literature supplied with the power source, or
contact your local power source representative.

Before attempting to open or service the
pump:

1. Familiarize yourself with this man-

ual.

2. Lock out or disconnect the power

source to ensure that the pump will
remain inoperative.

3. Allow the pump to completely cool

if overheated.

4. Check the temperature before

opening any covers, plates, or
plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cau-

tiously.

7. Drain the pump.

If this pump has been approved for use
with volatile and/or flammable liquids,
be certain proper safety practices are
followed before operating or servicing
the pump. Provide adequate ventilation,
prohibit smoking, wear static-resistant
clothing and shoes. Clean up all fuel
spills immediately after occurrence.

Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam-
age to equipment. Suction and dis-
charge hoses and piping must be re-
moved from the pump before lifting.

Suction Check Valve Disassembly

Before attempting to service the pump, remove the
pump casing drain plug (35) and drain the pump.
Clean and reinstall the drain plug.

To service the suction check valve, remove the suc-
tion piping. Remove the nuts (39) securing the suc-
tion flange (40) and the check valve assembly (41)
to the pump casing (1). Pull the check valve assem-
bly from the suction port.

Inspect the check valve parts for wear or damage.
If replacement is required, remove the hardware
(45 and 46) and separate the valve gasket (42) and
weights (43 and 44).

If no further disassembly is required, see Suction
Check Valve Installation.

Advertising