Gorman-Rupp Pumps 04C3-B 407671 and up User Manual

Page 28

Advertising
background image

0 SERIES

OM-01218

MAINTENANCE & REPAIR

PAGE E - 8

IMPELLER

SHAFT

SEAL

PLATE

ROTATING

ELEMENT

RETAINER

SPRING

IMPELLER

ADJUSTING

SHIMS

IMPELLER

BELLOWS

SHAFT

SLEEVE

O‐RING

STATIONARY

SEAT

SPRING

HOLDER

Figure 2. Seal Assembly

This seal is not designed for operation at
temperatures above 160

_F (71_C). Do not

use at higher operating temperatures.

Position the seal plate (13) on a flat surface with the
impeller side facing up. If the wear ring (12) was re­
moved, press the replacement ring into the seal
plate until it seats squarely against the bore shoul­
der.

The wear ring must seat squarely in the
seal plate bore or binding and/or exces­
sive wear will result.

Subassemble the O‐ring onto the stationary ele­
ment and use even pressure to press this subas­
sembly into the seal plate until it seats squarely
against the shoulder bore

Carefully slide the assembled seal plate and sta­
tionary seal element over the shaft. Use caution not
to nick or damage the stationary seat on the shaft
threads. Temporarily secure the seal plate to the
pedestal (24) using two capscrews and nuts (not
supplied).

Lubricate the I.D. of the bellows with water, and
slide the rotating portion of the seal over the shaft
sleeve until the seal face is just flush with the un­
dercut end of the sleeve.

Slide the assembled shaft sleeve and rotating por­
tion of the seal onto the shaft until the polished
faces contact. Continue to push the sleeve through
the seal until it is fully seated against the shaft
shoulder.

Install the seal spring and spring holder (38).

Impeller Installation

Inspect the impeller and replace it if cracked or
badly worn.

For maximum pump efficiency, the impeller should
be centered within the volute scroll.

Advertising