Pump and seal disassembly and reassembly – Gorman-Rupp Pumps 06B3-B 806819 and up User Manual

Page 24

Advertising
background image

0 SERIES

OM-01224

MAINTENANCE & REPAIR

PAGE E - 4

PUMP AND SEAL DISASSEMBLY
AND REASSEMBLY

Review all SAFETY information in Section A.

Follow the instructions on all tags, label and de­
cals attached to the pump.

This pump requires little service due to its rugged,
minimum‐maintenance design. However, if it be­
comes necessary to inspect or replace the wearing
parts, follow these instructions which are keyed to
the sectional view (see Figure 1) and the accompa­
nying parts list.

This manual will alert personnel to known proce­
dures which require special attention, to those
which could damage equipment, and to those
which could be dangerous to personnel. However,
this manual cannot possibly anticipate and provide
detailed precautions for every situation that might
occur during maintenance of the unit. Therefore, it
is the responsibility of the owner/maintenance per­
sonnel to ensure that only safe, established main­
tenance procedures are used, and that any proce­
dures not addressed in this manual are performed
only after establishing that neither personal safety
nor pump integrity are compromised by such prac­
tices.

Before attempting to service the pump, switch off
the engine ignition and disconnect the positive bat­
tery cable to ensure that the pump will remain inop­
erative. Close all valves in the suction and dis­
charge lines.

For power source disassembly and repair, consult
the literature supplied with the power source, or
contact your local power source representative.

Before attempting to open or service the
pump:

1. Familiarize yourself with this man­

ual.

2. Lock out or disconnect the power

source to ensure that the pump will
remain inoperative.

3. Allow the pump to completely cool

if overheated.

4. Check the temperature before

opening any covers, plates, or
plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cau­

tiously.

7. Drain the pump.

If this pump is used for volatile and/or
flammable liquids, be certain proper
safety practices are followed before op­
erating or servicing the pump. Provide
adequate ventilation, prohibit smoking,
wear static‐resistant clothing and
shoes. Clean up all fuel spills immedi­
ately after occurrence.

Pump Disassembly

Death or serious personal injury and
damage to the pump or components
can occur if proper lifting procedures
are not observed. Make certain that
hoists, chains, slings or cables are in
good working condition and of suffi­
cient capacity and that they are posi­
tioned so that loads will be balanced
and the pump or components will not be
damaged when lifting. Suction and dis­
charge hoses and piping must be re­
moved from the pump before lifting. Lift
the pump or component only as high as
necessary and keep personnel away
from suspended objects.

Before attempting to service the pump, remove the
pipe plug (37) and drain the pump. Clean and rein­
stall the pipe plug.

To service the wear ring (36), impeller (2), seal as­
sembly (3), or seal plate (11), the pump casing (1)
must be separated from the base and pedestal
(30).

Advertising