Gorman-Rupp Pumps 04A20-B 818101 and up User Manual

Page 30

Advertising
background image

0 SERIES

OM-01206

MAINTENANCE & REPAIR

PAGE E - 10

LUBRICATION

Seal Assembly

Fill the bottle oiler (16) with SAE No. 30 non‐deterg­
ent oil. Check the oil level regularly and keep the
bottle oiler full.

Bearings

The pedestal was fully lubricated when shipped
from the factory. Check the oil level regularly
through the sight gauge (33)

and maintain it at the

middle of the gauge. When lubrication is required,
add SAE No. 30 non‐detergent

oil through the hole

for the air vent (22). Do not over‐lubricate. Over‐lu­
brication can cause the bearings to over‐heat, re­
sulting in premature bearing failure.

NOTE

The white reflector in the sight gauge must be posi­
tioned horizontally to provide proper drainage.

Under normal conditions, drain the bearing hous­

ing once each year and refill with clean oil. Change

the oil more frequently if the pump is operated con­

tinuously or installed in an environment with rapid

temperature change.

Monitor the condition of the bearing lubri­
cant regularly for evidence of rust or mois­
ture condensation. This is especially im­
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory for

the recommended grade of oil.

Advertising