OM-01207

0 SERIES

MAINTENANCE & REPAIR

PAGE E - 5

separate the pump casing and gasket (36) from
the seal plate and pedestal.

Tie and tag any leveling shims used under the cas­
ing feet to ease reassembly.

Inspect the wear ring (42) for excessive wear or
scoring. The wear ring is secured in the pump cas­
ing by a press fit. If replacement is required, use a
small bit to drill two holes through the ring horizon­
tally, 180

_ apart. Use a saw or chisel to complete

the cuts through the ring, and remove it from the
pump casing. Use caution not to damage the
pump casing bore when removing the wear ring.

Use caution not to damage the pump cas­
ing bore when removing the wear ring.

Impeller Removal

Immobilize the impeller by inserting a bar between
the impeller vanes, being careful not to damage
the vanes. Disengage the hardware (45, 46 and
47). Remove the bar from the impeller.

Install 3/8-16 UNC by 4‐inch long capscrews in
the tapped holes in the impeller. Use the caps­
crews and a suitable puller to remove the impeller
from the shaft. Use caution when removing the im­
peller; tension on the seal spring will be released as
the impeller is removed. Retain the impeller key (9).

Remove the impeller adjusting shims (53). Tie and
tag the shims or measure and record their thick­
ness for ease of reassembly.

Seal Removal and Disassembly

(Figures 1 and 2)

Remove the seal spring. Slide the shaft sleeve (10)
and rotating portion of the seal off the shaft as a
unit.

Apply oil to the sleeve and work it up under the rub­
ber bellows. Slide the rotating portion of the seal off
the shaft sleeve.

Use caution not to damage the seal plate
bore when removing the wear ring.

Remove the machine screws (48) and slide the
seal plate and stationary portion of the seal off the
impeller shaft (20) as a unit. Press the stationary
seal element and O‐ring out of the seal plate from
the back side.

Inspect the wear ring (51) for excessive wear or
damage. The wear ring is secured in the seal plate
by a press fit. If replacement is required, use a
small bit to drill three to four holes through the ring
horizontally, equal distances apart. Use a saw or
chisel to complete the cuts through the ring, and
remove it from the seal plate. Use caution not to
damage the seal plate bore when removing the
wear ring.

Shaft And Bearing Removal And Disassembly

When the pump is properly operated and main­
tained, the pedestal should not require disassem­
bly. Disassemble the shaft and bearings only
when there is evidence of wear or damage.

Shaft and bearing disassembly in the field
is not recommended. These operations
should be performed only in a properly
equipped shop by qualified personnel.

Remove the pedestal drain plug (29) and drain the
lubricant. Clean and reinstall the drain plug.

Remove the slinger ring (33). Disengage the hard­
ware (12 and 13) and slide the assembled bearing
cap (32) and oil seal (14) off the shaft. Remove the
O‐ring (31). Press the oil seal from the bearing cap.

Use snap ring pliers to remove the bearing retain­
ing ring (23) from the pedestal bore. Remove the
bearing shim set (24); tie and tag the shims, or
measure and record their thickness for ease of
reassembly.

Loosen, but do not remove, the machine screws
(21). Pry the retainer from the pedestal bore using

Advertising