Gorman-Rupp Pumps 04A52-B 1326393 and up User Manual

Page 29

Advertising
background image

0 SERIES

OM-01231

MAINTENANCE & REPAIR

PAGE E - 10

Fill the pump casing with clean liquid. Reinstall the
fill plug (52) and tighten it.

Refer to OPERATION, Section C, before putting
the pump back into service.

LUBRICATION

Seal Assembly

The seal assembly is lubricated by the medium be­
ing pumped and no additional lubrication is re­
quired.

Bearing

The pedestal was fully lubricated when shipped
from the factory. Check the oil level regularly
through the sight gauge (27)

and maintain it at the

middle of the gauge. When lubrication is required,
add SAE No. 30 non‐detergent

oil through the hole

for the air vent (16). Do not over‐lubricate. Over‐lu­

brication can cause the bearings to over‐heat, re­
sulting in premature bearing failure.

NOTE

The white reflector in the sight gauge must be posi­
tioned horizontally to provide proper drainage.

Under normal conditions, drain the bearing hous­
ing once each year and refill with clean oil. Change
the oil more frequently if the pump is operated con­
tinuously or installed in an environment with rapid
temperature change.

Monitor the condition of the bearing lubri­
cant regularly for evidence of rust or mois­
ture condensation. This is especially im­
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory for
the recommended grade of oil.

Advertising