Gorman-Rupp Pumps 03F52-B 1329227 and up User Manual
Page 28
0 SERIES
OM-01190
MAINTENANCE & REPAIR
PAGE E - 10
hours of operation or once each month, whichever
comes first. Do not over‐lubricate. Over‐lubrication
can cause the bearing to over‐heat, resulting in
premature bearing failure.
If grease is forced out around the shaft as
new grease is added, the bearing cavity is
full and should be disassembled and
cleaned immediately.
There are no provisions in the bearing cavity to
drain or flush the lubricant. The pump and pedestal
must be disassembled to completely clean and
maintain this cavity.
Under normal conditions, change the grease after
each 5000 hours of operation, or at 12 month inter
vals, whichever comes first. Change the grease
more frequently if the pump is operated continu
ously or installed in an environment where variable
hot and cold temperatures are common.
When lubricating a dry pedestal, fill the cavity
through the hole for the vented plug (10) with ap
proximately 1/3 lb. (0.15 kg.) of grease (approxi
mately 1/3 full).
For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
lubricant.