Gorman-Rupp Pumps 54J20-B 1410811 and up User Manual
Page 7
Advertising
50 SERIES
OM-01342
PAGE A - 2
SAFETY
charge valve, pump components will
deteriorate, and the liquid could come
to a boil, build pressure, and cause the
pump casing to rupture or explode.
Do not remove plates, covers, gauges,
pipe plugs, or fittings from an over
heated pump. Vapor pressure within the
pump can cause parts being disen
gaged to be ejected with great force. Al
low the pump to cool before servicing.
Overheated pumps can cause severe
burns and injury. If overheating of the
pump occurs:
1. Stop the pump immediately.
2. Allow the pump to completely cool.
3. Refer to instructions in this manual
before restarting the pump.
Pumps and related equipment must be in
stalled and operated according to all na
tional, local and industry standards.