Gorman-Rupp Pumps VGH4C31-B 1379872 thru 1210169 User Manual

Page 32

Advertising
background image

VGH SERIES

OM−06126

MAINTENANCE & REPAIR

PAGE E − 10

Do not fill the bearing cavity through the vent plug
in the top of the housing. This will result in over-fill-
ing, and can cause leakage, excessive heat build-
up and/or premature bearing failure.

Check the oil level regularly through the constant
level oiler and add oil as required.

Under normal conditions, drain the bearing hous-
ing once each year and refill with clean oil. Change
the oil more frequently if the pump is operated con-
tinuously or installed in an environment with rapid
temperature change.

Monitor the condition of the bearing lubri-
cant regularly for evidence of rust or mois-
ture condensation. This is especially im-
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Power Source

Consult the literature supplied with the power
source, or contact your local power source repre-
sentative.

Advertising