Gorman-Rupp Pumps VG5C3-B 1188885 and up User Manual

Page 13

Advertising
background image

OM-02816

VG SERIES

PAGE B - 6

INSTALLATION

Check parallel adjustment by laying a straightedge
across both coupling rims at the top, bottom, and
side. When the straightedge rests evenly on both
halves of the coupling, the coupling is in horizontal
parallel alignment. If the coupling is misaligned,
use a feeler gauge between the coupling and the
straightedge to measure the amount of misalign­
ment.

V‐Belt Drives

When using V‐belt drives, the power source and
the pump must be parallel. Use a straightedge
along the sides of the pulleys to ensure that the pul­
leys are properly aligned (see Figure 3C). In drive
systems using two or more belts, make certain that
the belts are a matched set; unmatched sets will
cause accelerated belt wear.

MISALIGNED:

SHAFTS

NOT PARALLEL

MISALIGNED:

SHAFTS

NOT IN LINE

ALIGNED: SHAFTS

PARALLEL AND

SHEAVES IN LINE

Figure 3C. Alignment of V‐Belt Driven Pumps

Tighten the belts in accordance with the belt manu­
facturer's instructions. If the belts are too loose,
they will slip; if the belts are too tight, there will be
excessive power loss and possible bearing failure.
Select pulleys that will match the proper speed ra­
tio; overspeeding the pump may damage both
pump and power source.

Do not operate the pump without the
guard in place over the rotating parts

.

exposed rotating parts can catch cloth­
ing, fingers, or tools, causing severe in­
jury to personnel.

Advertising