OM−03290

VG SERIES

PAGE A − 2

SAFETY

Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam-
age to equipment. Suction and dis-
charge hoses and piping must be re-
moved from the pump before lifting.

Do not remove plates, covers, gauges,
pipe plugs, or fittings from an over-
heated pump. Vapor pressure within the
pump can cause parts being disen-
gaged to be ejected with great force. Al-
low the pump to completely cool before
servicing.

After the pump has been positioned,
make certain that the pump and all pip-
ing connections are tight, properly sup-
ported and secure before operation.

Pumps and related equipment must be in-
stalled and operated according to all na-
tional, local and industry standards.

Overheated pumps can cause severe
burns and injuries. If overheating of the
pump occurs:

1. Stop the pump immediately.
2. Ventilate the area.
3. Allow the pump to completely cool.
4. Check the temperature before

opening any covers, plates,
gauges, or plugs.

5. Vent the pump slowly and cau-

tiously.

6. Refer to instructions in this manual

before restarting the pump.