INSTALLATION

straightedge to measure the amount of misalign-
ment.

Figure 5. Aligning Non-Spider Type Couplings

V-Belt Drives

When using V-belt drives, the power source and
the pump must be parallel. Use a straightedge
along the sides of the pulleys to ensure that the pul-
leys are properly aligned (see Figure 6). In drive
systems using two or more belts, make certain that
the belts are a matched set; unmatched sets will
cause accelerated belt wear.

SHAFTS

NOT

PARALLEL

SHAFTS

NOT

IN LINE

MISALIGNED

SHAFTS PARALLEL

AND

SHEAVES IN LINE

ALIGNED

Figure 6. Alignment of V-Belt Driven Pumps

Tighten the belts in accordance with the belt manu-
facturer’s instructions. If the belts are too loose,
they will slip; if the belts are too tight, there will be
excessive power loss and possible bearing failure.
Select pulleys that will match the proper speed ra-
tio; over speeding the pump may damage both
pump and power source.

Do not operate the pump without the
guard in place over the rotating parts.
Exposed rotating parts can catch cloth-
ing, fingers, or tools, causing severe in-
jury to personnel.

Advertising