Gorman-Rupp Pumps 66B2-B 370671 and up User Manual

Page 29

Advertising
background image

OM−01454

60 SERIES

MAINTENANCE & REPAIR

PAGE E − 7

a press to reposition the bearings against the re-
taining rings.

If heating the bearings is not practical, use a suit-
ably sized sleeve and an arbor (or hydraulic) press
to install the bearings on the shaft.

When installing the bearings onto the
shaft, never press or hit against the outer
race, balls, or ball cage. Press only on the
inner race.

Slide the shaft and assembled bearings into the
pedestal bore until the inboard bearing is fully
seated against the pedestal shoulder.

When installing the shaft and bearings into
the bearing bore, push against the outer
race. Never hit the balls or ball cage.

Lubricate the shaft in the area of the oil seal (9) and
press the oil seal into the pedestal with the lip posi-
tioned as shown in Figure 1. Use caution not to roll
or cut the lip of the oil seal on the shaft keyway.

Install the same thickness of bearings shims (21)
as previously removed.

Install the pedestal foot (20) and secure the bear-
ing cap and foot to the pedestal using the hard-
ware (18 and 19). Check shaft endplay.

NOTE

Impeller shaft endplay should be between .002 and
.010 inch (0,05 mm to 0,25 mm). Add or remove
bearing shims to establish the correct endplay.

Install the slinger ring (8).

Lubricate the bearing cavity as indicated in LUBRI-
CATION at the end of this section.

Pump Casing and Balance Ring Installation

If the balance ring (27) was removed at disassem-
bly, press the replacement ring into the pump cas-
ing until fully seated.

The balance ring must seat squarely in the
casing bore or binding and/or excessive
wear will result.

Inspect the bore of the seal liner (11) for wear or
grooves which might cause leakage or damage to
the seal packing rings. If the seal liner requires re-
placement, see Seal Installation for replacement
instructions before proceeding to install the pump
casing.

Use a suitable lifting device to position the pup cas-
ing against the pedestal (22) so the lubrication hole
in the casing aligns with the hole in the pedestal,
and secure it with the previously removed hard-
ware (23 and 24).

Reinstall the grease cup and piping (5, 6 and 7) in
the pump casing.

Seal Installation

(Figures 1 and 3)

Clean the seal cavity and shaft with a cloth soaked
in fresh cleaning solvent.

Most cleaning solvents are toxic and
flammable. Use them only in a well ven-
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain-
ers.

Inspect the impeller shaft for damage. Small
scratches or nicks may be removed with a fine file
or emery cloth. If excessive wear exists, the shaft
will have to be replaced.

The seal is not normally reused because wear pat-
terns on the finished faces cannot be realigned
during reassembly. This could result in premature

Advertising