Safety ‐ section a – Gorman-Rupp Pumps 612L20B-B 806819 and up User Manual

Page 6

Advertising
background image

60 SERIES

OM-01919

PAGE A - 1

SAFETY

SAFETY ‐ SECTION A

This information applies to 60 Series ba­
sic pumps. Gorman‐Rupp has no con­
trol over or particular knowledge of the
power source which will be used. Refer
to the manual accompanying the power
source before attempting to begin oper­
ation.

Because pump installations are seldom
identical, this manual cannot possibly
provide detailed instructions and pre­
cautions for each specific application.
Therefore, it is the owner/installer's re­
sponsibility to ensure that applications
not addressed in this manual are per­
formed only after establishing that nei­
ther operator safety nor pump integrity
are compromised by the installation.

Before attempting to open or service the
pump:

1. Familiarize yourself with this man­

ual.

2. Disconnect or lock out the power

source to ensure that the pump will
remain inoperative.

3. Allow the pump to completely cool

if overheated.

4. Check the temperature before

opening any covers, plates, or
plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cau­

tiously.

7. Drain the pump.

This pump is designed to handle waste­
water, mud or slurries containing speci­
fied entrained solids. Do not attempt to
pump volatile, corrosive or flammable

liquids which may damage the pump or
endanger personnel as a result of pump
failure.

Death or serious personal injury and
damage to the pump or components
can occur if proper lifting procedures
are not observed. Make certain that
hoists, chains, slings or cables are in
good working condition and of suffi­
cient capacity and that they are posi­
tioned so that loads will be balanced
and the pump or components will not be
damaged when lifting. Suction and dis­
charge hoses and piping must be re­
moved from the pump before lifting. Lift
the pump or component only as high as
necessary and keep personnel away
from suspended objects.

After the pump has been positioned,
make certain that the pump and all pip­
ing or hose connections are tight, prop­
erly supported and secure before oper­
ation.

Do not operate the pump against a
closed discharge valve for long periods
of time. If operated against a closed dis­
charge valve, pump components will
deteriorate, and the liquid could come
to a boil, build pressure, and cause the
pump casing to rupture or explode.

Do not remove plates, covers, gauges,
pipe plugs, or fittings from an over­

Advertising