Gorman-Rupp Pumps 612L20-B 814882 and up User Manual

Page 13

Advertising
background image

OM−01395

60 SERIES

PAGE B − 6

INSTALLATION

MISALIGNED:

SHAFTS

NOT PARALLEL

MISALIGNED:

SHAFTS

NOT IN LINE

ALIGNED: SHAFTS

PARALLEL AND

SHEAVES IN LINE

Figure B−5. Alignment of V-Belt Driven

Pumps

Tighten the belts in accordance with the belt manu-
facturer’s instructions. If the belts are too loose,
they will slip; if the belts are too tight, there will be
excessive power loss and possible bearing failure.

Select pulleys that will match the proper speed ra-
tio; overspeeding the pump may damage both
pump and power source.

Do not operate the pump without the
guard in place over the rotating parts.
Exposed rotating parts can catch cloth-
ing, fingers, or tools, causing severe in-
jury to personnel.

V-Belt Jack Shaft Drives

If the pump is to be driven at speeds exceeding
1050 rpm, the V-belts must operate through a jack
shaft arrangement to protect the shaft bearings
from excessive stress. Failure to use a jack shaft on
high speed applications will result in premature
shaft bearing failure.