D SERIES

OM--01505

MAINTENANCE & REPAIR

PAGE E -- 16

Gearbox

(Figure 4)

The gearbox was fully lubricated when shipped
from the factory. Check the oil level regularly at the
oil cup (46), and keep the oil cup full. Lubricate with
SAE No. 30 non-detergent when lubrication is re-
quired.

Do not over-lubricate. Over-lubrication can

cause the bearings to overheat, resulting in prema-
ture bearing failure.

Under normal conditions, change the oil after each
5000 hours of operation, or at 12 month intervals,
whichever occurs first. Change the oil more fre-
quently if the pump if operated continuously or in-
stalled in a dirty or humid environment with rapid
temperature change.

Monitor the condition of the bearing lubri-

cant regularly for evidence of rust or mois-

ture condensation. This is especially im-

portant in areas where variable hot and

cold temperatures are common.

When lubricating a dry (or overhauled) gearbox,
add one ounce of ‘Molykote M Gear Guard’ and
‘top off’ with clean oil.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Motor

Refer to the motor manufacturer’s recommenda-
tions or contact your local motor representative.

Advertising