Gorman-Rupp Pumps PAH4A60-6068H 1511893 and up User Manual
Page 49
PAH SERIES
OM-06441
MAINTENANCE & REPAIR
PAGE E - 26
bearing cavity with approximately 50 ounces (1,5
liters). Clean and reinstall the air vent. Do not over‐
lubricate. Over‐lubrication can cause the bearings
to over‐heat, resulting in premature bearing failure.
NOTE
The white reflector in the sight gauge must be posi
tioned horizontally to provide proper drainage.
Under normal conditions, drain the bearing hous
ing once each year and refill with clean oil. Change
the oil more frequently if the pump is operated con
tinuously or installed in an environment with rapid
temperature change.
Monitor the condition of the bearing lubri
cant regularly for evidence of rust or mois
ture condensation. This is especially im
portant in areas where variable hot and
cold temperatures are common.
For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.
Engine
Consult the literature supplied with the engine, or
contact your local engine representative.