Gorman-Rupp Pumps PAH3A60C-B 1524589 and up User Manual

Page 40

Advertising
background image

OM-06472

PAH SERIES

MAINTENANCE & REPAIR

PAGE E - 19

LUBRICATION

(Figure 3)

Seal Assembly

Before starting the pump, remove the air vent (12)
and fill the seal cavity with approximately 5 quarts
(4,7 liters) of SAE No. 30 non‐detergent oil or to the
center of the sight gauges (9). Clean and reinstall
the vented plug. Maintain the oil level at the middle
of the sight gauges.

Bearings

(Figure 3)

The bearing housing was fully lubricated when
shipped from the factory. Check the oil level regu­
larly through the sight gauges (9A)

and maintain it

at the midpoint of the gauges. When lubrication is
required, remove the air vent (12A) and add SAE
No. 30 non‐detergent oil through the opening.
When lubricating a dry (overhauled) intermediate,
fill the bearing cavity with approximately 50 ounces
(1,5 liter). Clean and reinstall the air vent. Do not
over‐lubricate. Over‐lubrication can cause the
bearings to over‐heat, resulting in premature bear­
ing failure.

NOTE

The white reflector in the sight gauge must be posi­
tioned horizontally to provide proper drainage.

Under normal conditions, drain the bearing hous­
ing once each year and refill with clean oil. Change
the oil more frequently if the pump is operated con­
tinuously or installed in an environment with rapid
temperature change.

Monitor the condition of the bearing lubri­
cant regularly for evidence of rust or mois­
ture condensation. This is especially im­
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Power Source

Consult the literature supplied with the power
source, or contact your local power source repre­
sentative.

Advertising