Gorman-Rupp Pumps PA6C60C-F4L 1504811 and up User Manual

Page 17

Advertising
background image

OM-05768

PA SERIES

OPERATION

PAGE C - 4

pletely cool before servicing. Do not re­
move plates, covers, gauges, or fittings
from an overheated pump. Liquid within
the pump can reach boiling tempera­
tures, and vapor pressure within the
pump can cause parts being disen­
gaged to be ejected with great force. Af­
ter the pump cools, drain the liquid from
the pump by removing the casing drain
plug. Use caution when removing the
plug to prevent injury to personnel from
hot liquid.

Strainer Check

Check the strainer regularly, and clean it as neces­
sary. The strainer should also be checked if pump
flow rate begins to drop. Monitor and record the
vacuum suction gauge readings regularly to detect
strainer blockage.

Never introduce air or steam pressure into the
pump casing or piping to remove a blockage. This
could result in personal injury or damage to the
equipment. If backflushing is absolutely neces­
sary, liquid pressure must be limited to 50% of the
maximum permissible operating pressure shown
on the pump performance curve.

STOPPING

Manual Stopping

Never halt the flow of liquid suddenly. If the liquid
being pumped is stopped abruptly, damaging
shock waves can be transmitted to the pump and
piping system. Close all connecting valves slowly.

Reduce the throttle speed slowly and allow the en­
gine to idle briefly before stopping.

In the manual mode, reduce the throttle speed
slowly, and allow the engine to idle briefly before
turning the key switch to `OFF'.

If the application involves a high discharge
head, gradually close the discharge
throttling valve before stopping the pump.

After stopping the pump, switch off the engine igni­
tion and remove the key to ensure that the pump
will remain inoperative.

Automatic Stopping

In the automatic mode, the pump will stop when
the liquid in the wet well or sump lowers and acti­
vates the “Off” float switch(s). The pump will restart
automatically when the liquid rises and activates
the “On” float switch(s).

Safety Shutdown System

The unit is equipped with a safety system to auto­
matically shut down the engine under certain con­
ditions. The engine will automatically shut down:

1. If the engine exceeds its safe operating tem­

perature.

2. If the engine oil pressure drops below design

limits.

3. If the engine fails to start within a pre‐set peri­

od of time.

4. If the engine speed exceeds the safe operat­

ing range.

5. If the engine fan belt breaks.

Lights on the control panel will indicate which of the
safety features has caused the engine to shut
down.

Should any of the safety features cause the engine
to shut down, the cause must be determined and
corrected
before putting the unit back into service.
The engine will not restart until the key switch has
been returned to the `OFF' position for at least 10
seconds.

All safety shutdown features are pre‐set at the fac­
tory for optimum performance and safety; do not
attempt to adjust these settings.

Never disconnect any of the safety shut­
down features; this will void the warran­
ty and could result in serious damage to
the unit and/or injury to personnel. Safe­

Advertising