OM−06250

PA SERIES

MAINTENANCE & REPAIR

PAGE E − 19

O-RING

IMPELLER

STATIONARY

SEAT

ROTATING ELEMENT

BELLOWS

IMPELLER

SHIMS

IMPELLER

SPRING

RETAINER

SHAFT

DRIVE BAND

PUMP CASING

SHAFT SLEEVE

SHAFT SLEEVE

O-RING

IMPELLER

KEY

Figure 9. Seal Assembly

This seal is not designed for operation at
temperatures above 160

_F (71_C). Do not

use at higher operating temperatures.

Inspect the pump casing and impeller shaft for
burrs or sharp corners and remove any that exist.

With the stationary seat O-ring lubricated and
installed in the stationary seat, press the stationary
seat into the pump casing until it seats squarely
against the bore shoulder. A push tube cut from a
length of plastic pipe would aid this installation.
The O.D. of the pipe should be approximately the
same diameter as the O.D. of the seal spring.

Lubricate the shaft sleeve O-ring (6) and slide it
onto the shaft until it seats against the shaft shoul-
der.

Use even pressure to carefully press this rotating
portion of the seal onto the lubricated sleeve (5) un-

til the seal face is just flush with the chamfered end
of the sleeve.

Slide the assembled shaft sleeve and rotating por-
tion of the seal onto the shaft until the seal faces
contact. Continue to push the sleeve through the
seal until it seats squarely against the shaft shoul-
der.

Install the seal spring.

Impeller Installation

(Figure 4)

If the balance ring (38) was removed, press the re-
placement ring into the pump casing as described
in Pump Casing Installation.

The balance ring must seat squarely in the
suction head; otherwise binding and/or ex-
cessive wear will result.