Gorman-Rupp Pumps PA6C60-4045H 1485126 and up User Manual

Page 45

Advertising
background image

OM−06081

PA SERIES

MAINTENANCE & REPAIR

PAGE E − 25

LUBRICATION

(Figure 5)

Seal Assembly

Fill the seal cavity through the hole for the vented
plug (5) with SAE No. 30 non-detergent oil. Check
the oil level regularly and refill as required. When lu-
bricating a dry seal cavity, add approximately
approximately 256 oz. or 8 U.S. quarts (7,6 liters) of
oil to level indicated.

Bearings

(Figure 5)

The bearing housing was fully lubricated when
shipped from the factory. Check the oil level regu-
larly through the sight gauges (25)

and maintain it

at the midpoint of the gauge. When lubrication is
required, remove the air vent (6) and add SAE No.
30 non-detergent oil through the opening. When
lubricating a dry (overhauled) bearing housing, fill
the bearing cavity with approximately 40 ounces
(1,2 liters) of oil. Clean and reinstall the air vent. Do
not over-lubricate. Over-lubrication can cause the
bearings to over-heat, resulting in premature bear-
ing failure.

NOTE

The white reflector in the sight gauge must be posi-
tioned horizontally to provide proper drainage.

Under normal conditions, drain the bearing hous-
ing once each year and refill with clean oil. Change
the oil more frequently if the pump is operated con-
tinuously or installed in an environment with rapid
temperature change.

Monitor the condition of the bearing lubri-
cant regularly for evidence of rust or mois-
ture condensation. This is especially im-
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Engine

Consult the literature supplied with the engine, or
contact your local engine representative.

Advertising