OM-06168

PA SERIES

MAINTENANCE & REPAIR

PAGE E - 27

If the orifice button was removed, screw the new
orifice button into the linkage bar until fully seated.
Align the hole in the linkage bar with the holes in the
bracket and reinstall the pivot pin. Secure the pivot
pin with the previously removed “e‐clip”.

Adjust the orifice button seating as necessary by
screwing the orifice button into or out of the linkage
bar. Proper adjustment is achieved when the ori­
fice button fully seats against the orifice before the
linkage bar on the float bottoms against the
threads on the orifice button. When adjustment is
complete, install and tighten the lock washer and
hex nut securing the orifice button.

Install the strainer (6) and priming valve gasket (4).

Lower the float into the priming chamber (5) and
secure the priming valve with the previously re­
moved hardware (2 and 3).

(Figure 5)

Install the baffle (9) and gasket (8) and use a sling
and suitable lifting device to position the priming
chamber assembly on the hopper spool (32, Fig­
ure 3). Secure the priming chamber assembly with
the hardware (6 and 7).

Reconnect the suction piping to the hopper spool
and the air discharge tubing to the priming cham­
ber assembly.

LUBRICATION

Seal Assembly

(Figure 5)

Before starting the pump, remove the vented plug
(10) and fill the seal cavity with approximately 5
quarts (4,7 liters) of SAE No. 30 non‐detergent oil
or to the center of the sight gauge (4, Figure 4).
Clean and reinstall the vented plug. Maintain the oil
level at the middle of the sight gauge.

Bearings

(Figure 5)

The bearing housing was fully lubricated when
shipped from the factory. Check the oil level regu­
larly through the sight gauge (13)

and maintain it at

the midpoint of the gauge. When lubrication is re­
quired, remove the air vent (12) and add SAE No.
30 non‐detergent oil through the opening. When
lubricating a dry (overhauled) intermediate, fill the
bearing cavity with approximately 28 ounces (0,8
liter). Clean and reinstall the air vent. Do not over‐
lubricate. Over‐lubrication can cause the bearings
to over‐heat, resulting in premature bearing failure.

NOTE

The white reflector in the sight gauge must be posi­
tioned horizontally to provide proper drainage.

Under normal conditions, drain the bearing hous­
ing once each year and refill with clean oil. Change
the oil more frequently if the pump is operated con­
tinuously or installed in an environment with rapid
temperature change.

Monitor the condition of the bearing lubri­
cant regularly for evidence of rust or mois­
ture condensation. This is especially im­
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.

Engine

Consult the literature supplied with the engine, or
contact your local engine representative.