Gorman-Rupp Pumps PA4A60C-F3L 1303165 and up User Manual

Page 15

Advertising
background image

OM−05765

PA SERIES

OPERATION

PAGE C − 2

box to the START" position until the engine starts.
Release the key and the switch will return to the

RUN" position.

After the engine starts and the unit is fully primed,
adjust the engine RPM until the desired flow rate is
achieved.

Pump speed and operating condition
points must be within the continuous per-
formance range shown on the curve on
Page E-1.

Automatic Starting

If the unit is to be operated with the autostart con-
trol system, install the float(s) as described in
INSTALLATION, Section B.

Follow the procedures outlined for manual starting
and throttle adjustment, then turn the key to the

AUTO START" position.

NOTE

For security purposes, the key can be removed with
the switch in the AUTO START" position.

Press and hold the white AUTO" button on the
control panel until the red AUTO" light illuminates.
The auto-start system is now armed.

NOTE

The unit can continue to be started manually with
the keyswitch in the AUTO START" position by
pressing the white MAN" button on the control. The

Single Lightning Bolt" light on the control will illu-

minate in conjunction with an audible alarm before
the unit starts. The unit can then be stopped manu-
ally by pressing the OFF/SET" button.

In the auto-start mode, the Single Lightning Bolt"
light will illuminate in conjunction with an audible
alarm when the liquid level in the sump or wet well
rises and activates the float(s). The light will blink

and the alarm will sound for approximately 8 sec-
onds before the unit starts.

When the liquid level in the sump or wet well is suffi-
ciently pumped down, the unit will automatically
shut down.

NOTE

If the keyswitch is moved to the OFF" position
while in the auto-start mode, the engine will stop.
However, the auto-start process will continue as
soon as the keyswitch is moved back to the AUTO
START" position. To cancel the auto-start process,
press the OFF/SET" button.

The control panel is equipped with high oil temper-
ature, low oil pressure, V-belt and start failure (3 at-
tempts) safety shutdowns. If any of these problems
occur, the red Double Lightning Bolt" light will illu-
minate to indicate a system fault. When the prob-
lem is corrected, press the OFF/SET" button to re-
set the control.

NOTE

The OFF/SET" button has dual functionality when
in program mode. If necessary, consult the factory
for details on programming functions.

The unit can be started manually with the key-
switch in the AUTO START" position by pressing
the white MAN" button. The Single Lightning
Bolt" light will illuminate in conjunction with an au-
dible alarm before the unit starts.

Stop the unit manually by pressing the OFF/SET"
button.

Priming

The pump will begin to prime upon startup. The air
in the suction line will be discharged from the educ-
tor discharge line. Complete priming is indicated
by a positive discharge pressure reading.

If full priming is not achieved, the discharge check
valve may be malfunctioning. If this occurs, shut
down the pump and consult the separate Mainte-
nance and Repair manual for further details.

Advertising