Gorman-Rupp Pumps SE2D3A 115V 1P 1483930 and up User Manual

Page 31

Advertising
background image

OM-06495

SE SERIES

MAINTENANCE & REPAIR

PAGE E - 10

leads, lift the mounting plate (24) while guiding the
electrical leads through the grommet (27) to ac­
cess the centrifugal switch contact (90). Remove
the hardware (92, 93 and 94) and separate the mo­
tor lead terminals (91) from the contact.

Carefully remove the mounting plate; the bearing
shim (23) will become a free part. If required, disen­
gage the hardware (28, 29 and 30) securing the
green ground lead to the mounting plate.

NOTE

The centrifugal switch actuator (21) is a press fit
onto the rotor shaft and cannot be removed until the
rotor is removed.

See Head And Power Cable Installation if no fur­
ther disassembly is required.

Rotor And Shaft Removal

See PUMP END DISASSEMBLY and remove all
pump end components and Head And Power
Cable Removal
and remove the head and cable.

Carefully lift the rotor/shaft (95) with assembled
bearings (18 and 22) and centrifugal switch actua­
tor (21) from the motor housing. Use caution to pre­
vent the rotor from falling on the stator windings. If
necessary, tap the impeller end of the rotor shaft
with a block of wood or soft‐faced mallet to loosen
the seal between the bearing and the motor hous­
ing bore.

Bearing Removal

To prevent damage during removal from
the shaft, it is recommended that bearings
be cleaned and inspected in place. It is
strongly recommended that the bearings
be replaced any time the shaft and rotor
assembly is removed.

Before removing the bearings from the rotor shaft,
clean and inspect the bearings in place as follows.

Clean the bearings thoroughly in fresh cleaning
solvent. Dry the bearings with filtered compressed
air and coat with light oil.

Most cleaning solvents are toxic and
flammable. Use them only in a well ven­
tilated area; free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain­
ers.

Rotate the bearings by hand to check for rough­
ness or binding. If rotation is rough, replace the
bearings.

The bearing tolerances provide a tight press fit
onto the shaft and a snug slip fit into the upper and
lower mounting plates. Replace the shaft and rotor
(as an assembly) or the mounting plates if the
proper bearing fit is not achieved.

If replacement is required, use a bearing puller to
remove the bearings from the rotor shaft.

Centrifugal Switch Actuator Removal

Remove the snap ring securing the switch actuator
to the shaft. Use a felt tip ink marker to scribe the
location of the actuator on the shaft. Use a suitable
puller to remove the actuator from the shaft.

Stator Removal

Do not remove the stator (96) unless it is defective
(open windings, insulation resistance low, or stator
core damaged).

To remove the stator, position an expandable tool,
such as a split disc, approximately 2 inches (51
mm) inside the stator, and expand it tightly and
squarely on the I.D. Attach a lifting device to the lift­
ing eye of the tool, and raise the assembly approxi­
mately 1 inch (25 mm) off the work surface. Take
care not to damage the stator end turns.

The motor housing (97) must be heated with a
torch to expand it enough for the stator to be re­
moved. Apply heat evenly to the outside of the mo­
tor housing; excessive heat is not required. When
the motor housing is sufficiently heated, use a soft‐

Advertising