Gorman-Rupp Pumps S4B1-E50 460/3 1396095 and up User Manual

Page 49

Advertising
background image

OM-06099

S SERIES PUMPS

PAGE E - 23

MAINTENANCE AND REPAIR

stored in a clean, tightly closed container in a rea­
sonably dry environment.

Table E-2. Oil Quantity

Pump Model

Seal Cavity

Motor Cavity

S4B

256 ounces (10,4 liters)

160 ounces (2,8 liters)

Table E‐3. Pump Oil Specifications

Specifications:

Type

Premium high viscosity index, anti‐wear hydraulic oil

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viscosity (SSU @ 104

_F [40_C])

110 to 155

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dielectric

26,000 (volts‐min)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Acceptable alternate suppliers:

Gulf Oil Company

Gulf Harmony AW Hydraulic Fluid MG 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Texas Oil Company

Rando HD 32 or HD AZ 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sun Oil Company

Sunvis 816 or 916

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

BP (Also Boron)

Energol‐HLP 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Shell Oil Company

Tellus 32, Tellus T‐23 or T32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viscosity (SSU @ 210

_F [100_C])

40 to 50

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Recommended supplier:

Gulf Oil Company

Gulf Harmony 32 AW

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ARCO

Duro 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Exxon (Also Esso)

Nuto H 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Petro‐Canada

Harmony HVI 22

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Motor Housing Cavity

With the pump in an upright position, remove the
pipe cap (30) on the top of the pump. See Table E‐2
and add the recommended grade of lubricant
(Table E‐3) to the motor cavity. Maintain the oil at
this level
. Apply `Loctite Pipe Sealant With Teflon
No. 592' or equivalent sealant to the threads of the
street tee assembly (29). Reinstall and tighten the
cap.

Never attempt to fill the motor cavity
through the drain plug (11) opening or the
oil level plug (17). A volume of air must be
trapped above the motor to permit thermal
expansion of the motor oil.

Advertising