TROUBLE

POSSIBLE CAUSE

PROBABLE REMEDY

MOTOR RUNS BUT
FAILS TO DELIVER
RATED FLOW OR
PRESSURE

PUMP STARTS
THEN SHUTS OFF

EXCESSIVE
NOISE OR VIBRA­
TION

SFV SERIES X‐PROOF PUMPS

OM-06628

TROUBLESHOOTING

PAGE D - 2

Pump running backwards.

Check and correct impeller rotation
(see Rotation in Installation and
Operation Manual).

Voltage too low or too high; excessive

Check incoming voltage; check

voltage drop between pump and control. cable length.

Discharge head too high.

Reduce discharge head, or install
staging adaptor and additional pump.

Discharge throttling valve partially

Open discharge valve; check piping

closed; check valve improperly installed. installation.

Impeller or discharge line clogged.

Check and clear as necessary.

Liquid being pumped too thick.

Dilute liquid if possible.

Impeller worn or damaged.

Replace.

Insufficient liquid in wet well.

Stop pump until liquid level rises;
install liquid level devices.

Clogged suction port or impeller

Clear blockage; reset overload

causing motor to overload.

device in control box.

Motor overheated; thermal switch

Allow pump to cool.

tripped.

Moisture sensing device tripped.

Return pump to factory or authorized
repair facility.

Motor bearings defective.

Return pump to factory or authorized
repair facility.

Motor cable damaged.

Check (see Electrical Testing).

Insufficient liquid in wet well.

Stop pump until liquid level rises;
install liquid level devices.

Pump operating outside designed

Check discharge head and flow;

operating range.

adjust as required to meet perform‐
ance specifications.

Impeller clogged.

Clear blockage.

Impeller loose or damaged.

Check impeller; replace if necessary.

Motor shaft or bearings defective.

Replace.

Pumping entrained air.

Check wet well liquid level; install
baffles if required.