4.2 Description

The C-VLR model range has a connecting thread on the suction side and an exhaust silencer on the pres-
sure side. With the C-VLR 60 the incoming air is cleaned by a fi lter cartridge. The C-VLR 100-500 have a
micro fi lter on the suction side.
The ZEPHYR C-VLR is a double shaft rotary piston vacuum pump in which the claws roll off against each
other contact free and dry. The counter-rotating claw rotors are synchronised by a gear pair in the gearbox.
The synchronous gearbox gear wheels and the bearing on the motor side are lubricated with oil. These
components are in a gearbox that also contains the oil supply. Oil conveying devices always ensure that the
bearings and the gear wheels are suffi ciently supplied with oil at all permissible speeds. The feed chamber
has no sealants or lubricants. The C-VLR 400 and 500 sizes have grease lubricated bearings on the B side.
The gearbox and the compression chamber are separated from each other by special seals. The gearbox is
sealed from the outside with shaft seals and O rings, the compressor chamber with piston rings. Between
the two there is also another atmospherically ventilated area that can be loaded with sealing gas (special
version).
The C-VLR 100-500 is enclosed in an insulation hood.
In order to dissipate compression heat, the cooling air is sucked through between the machine and the hood
using drum fan that sucks in the fresh cooling air (Fig. 3/E) and discharges the heated air out of the cooling
air outlet (Fig. 3/F). The ZEPHYR VLR is driven by standard fl anged three phase motors via a coupling (with
an elastomer component).
A vacuum regulating valve (Fig. 2/C) is used to set the vacuum to the required values.

4.3

Areas of application

These contact free running claw vacuum pumps C-VLR can be operated constantly at any pressure between
atmospheric and an inlet pressure of:

100 mbar (abs.)

➝ C-VLR 60 / 150

150 mbar (abs.)

➝ C-VLR 100 / 120

200 mbar (abs.)

➝ C-VLR 250 / 251 / 300

250 mbar (abs.)

➝ C-VLR 400 / 500

The pumping capacity with unrestricted suction is 60, 100, 120, 150, 211, 235, 300, 385 and 500 m

3

/h at

50 Hz. Data sheet D 880 shows the dependency of the pumping capacity on the intake pressure.

If the unit is switched on more frequently (at regular
intervals of about 12 times an hour (C-VLR 60 - 150)
or 10 times an hour (C-VLR 250 - 500)) at higher
ambient temperatures and intake temperatures, the
excess temperature limit of the motor winding and
the bearings may be exceeded.Please contact the
manufacturer should the unit be used under such
conditions.