Malfunctions: Causes and elimination

Fault

Cause

Troubleshooting

Important

Final pressure (max.
vacuum) is not
reached

Machine or system leaking

Check the pipework and
screw connections for leaks
and to ensure that they are
fi rmly seated.

Section 7.2

Blades are worn or damaged

Replace blades

Section 7.2.2
Section 7.4

Machine gets too hot

Ambient or intake temperature
is too high

Ensure it is being used prop-
erly

Section 2.3

Cooling air supply is ob-
structed

Check environmental condi-
tions

Section 5.1

Clean ventilation slots

Section 7.2

The regulating valve is dirty so
that the permissible vacuum
value is exceeded.

Clean or replace the regulat-
ing valve

Section 7.2
Section 7.4

The machine makes
an abnormal noise

The compressor housing is
worn (chatter marks)

Repair by manufacturer or
authorised workshop

Elmo Rietschle
Service

The regulating valve is vibrat-
ing

Replace the valve

Section 7.4

Blades are damaged

Replace blades

Section 7.2.2
Section 7.4

Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.