Elmo Rietschle V-VTA 60/80/100/140 User Manual

Page 13

Advertising
background image

13

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

|

Bauj./Nr. 09

S1 3,00 / 3,60

kW

Typ VTR 100 (01)

150 mbar (abs.)

2849751

100 / 120 m³/h

EN 60034

1410 / 1700 min

-1

1027610116

3~

Mot.

Set up and operation

6

1

7

8

9

10

3

4

5

2

4.1.1 Data plate

Fig. 3 Data plate (example)

1

Type/ Size (mechanical version)

2

Year of construction

3 Motor

design

4 Serial

number

5 Item

no

6

Final pressure (abs.)

7

Pumping capacity 50 Hz / 60 Hz

8 Speed

50

Hz / 60

Hz

9

Motor output 50 Hz / 60 Hz

10 Operating

mode

4.2 Description

The V-VTA model range has a connecting thread on the suction side and an exhaust silencer on the pressure
side. The aspirated air is cleaned by an inbuilt fi ne micro fi lter. The carbon dust caused by the scoring of the
blades can be separated by an integral fi lter if necessary. A fan between the compressor housing and the
motor provides intensive air cooling. The compressor housing is located in a sound cover.
The machines are driven by standard fl anged three-phase motors using a coupling.
A vacuum regulating valve (Fig. 2/C) is used to set the vacuum to the required values with an upper limit.
Versions (01) to (30) have cooling exits from two sides whilst versions (31) to (60) have cooling exits on one
side only.

4.3

Areas of application

These dry running rotary vane vacuum pumps V-VTA 60, V-VTA 80, V-VTA 100 and V-VTA 140 are suitable
for evacuating closed systems and for a permanent vacuum in the intake pressure range 150 - 1000 mbar
(abs.).

The pumping capacity with unrestricted suction is 60, 80, 100 and 140 m

3

/h at 50 Hz. Data sheet D 250

shows the dependency of the pumping capacity on the intake pressure.

These dry running machines are suitable for conveying air with a relative humidity of 30 - 90%.

If the unit is switched on more frequently (at regular intervals of about 12 times (V-VTA 60 / 80)
resp. 10 times (V-VTA 100 / 140) an hour) or at higher ambient temperatures and intake tempera-
tures, the excess temperature limit of the motor winding and the bearings may be exceeded.
Please contact the manufacturer should the unit be used under such conditions

If it is installed in the open air the unit must be protected from environmental infl uences, (e.g. by a
protective roof).