Maintenance and repair

7

Maintenance and repair

DANGER

Danger of death from touching live parts.
Before maintenance work disconnect the machine
by pressing the main switch or unplugging it and
ensure that it cannot be turned on again.

WARNING

Hot surfaces and equipment
During maintenance work there is the danger of
getting burnt on hot components (Fig. 2/Q) and
by the machine lubricating oil.
Wait for the machine to cool down.

7.1 Maintenance

work

Regular maintenance work must be carried out in order to ensure operational safety.

Maintenance intervals also depend on the operational demands on the machine.

With any work observe the safety instructions described in Section 2.8 “Safety notes for installation, com-
missioning and maintenance”.

The whole unit should always be kept in a clean condition..

7.2 Maintenance

work

Interval

Maintenance tasks

Section

monthly

Check the pipes and screws for leaks and to ensure they are
seated properly and if necessary seal again or tighten up.

monthly

Check the terminal box and cable inlet holes for leaks and if
necessary re-seal.

monthly

Clean the ventilation slots on the machine and the motor
cooling ribs

depending on how dirty the
discharged medium is

Clean intake air fi lter

7.2.1

daily

Check the oil levels

7.2.2

500 - 2000 h

Change the oil

3000 h

Change the oil separator element

7.2.3

Advertising
This manual is related to the following products: