www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

|

Maintenance and repair

WARNING

Heavily contaminated air oil removing devices lead
to increased pump temperatures and in extreme
cases may cause the lubricating oil to ignite spon-
taneously.

The oil separator elements (5x) can become con-
taminated by dust particles after they have been
running for some time (power consumption and
pump temperature increase). Replace these compo-
nents (Fig. 7/L) every 2000 operating hours or when
the fi lter resistance is 0.7 bar (see pressure gauge

Accessories, Checking with short term, atmospheric
suction) because it is not possible to clean them.
Reduce the change intervals accordingly depending
on how contaminated the discharged medium is.
Changing: Undo the air oil removers (Fig. 7/L) with a
ring spanner (spanner width 19 mm or 3/4”) rotating
counter clockwise. Insert new air oil removers with
the open lock symbol (see Fig. 8) with the arrow

on the insert and fi x turning clockwise (until it clicks
into place).

7.2.4 Oil removal

open

closed

Fig. 8 Air oil remover