Elmo Rietschle G-BH7 Operating instructions User Manual

Page 9

Advertising
background image

Technical Data

© Gardner Denver Deutschland GmbH

9 / 28

610.44436.40.000

Noise level

Measuring-surface sound-pressure level as per
EN ISO 3744, measured at a distance of 1 m
[3.28 ft] at an operating point of approximately
2/3 of the permissible total pressure difference
with the lines connected without a vacuum or
pressure relief valve, tolerance ±3 dB (A).

Single-impeller design

Model

1-m measuring-surface

sound pressure level L

[dB (A)]

50 Hz

60 Hz

2BH7210-0..1.-. 70

2BH7310-0..1.-. 70

2BH7310-0..2.-. 70

2BH7410-0..1.-. 70

2BH7510-0..1.-. 70

2BH7510-0..2.-. 70

2BH7610-0..1.-. 71

2BH7610-0..3.-.

70

71

Two-impeller design

Model

1-m measuring-surface

sound pressure level L

[dB (A)]

50 Hz

60 Hz

2BH7220-0..2.-. 70

2BH7220-0..5.-. 70

2BH7320-0..5.-. 70

2BH7420-0..2.-. 70

2BH7420-0..5.-. 70

2BH7520-0..2.-. 70

2BH7520-0..7.-. 71

2BH7620-0..3.-. 71

2BH7620-0..5.-.

70

72

Three-impeller design

Model

1-m measuring-surface

sound pressure level L

[dB (A)]

50 Hz

60 Hz

2BH7530-0..8.-. 67 73

2BH7630-0..6.-. 77 80




Temperature increase

The information listed in the following tables
corresponds to the heating of vacuum
pump/compressor housings and the air exiting
compared to the ambient temperature during
operation with a permissible total pressure
difference and an air pressure of 1,013 mbar
[14.7 psi]. At lower air pressures these values
increase.

Single-impeller design

Model

Temperature increase

∆T [K]

approx.

[F]

approx.

50 Hz 60 Hz 50 Hz 60 Hz

2BH7210-0..1.-.

52 61 94 110

2BH7310-0..1.-.

61 61 110 110

2BH7310-0..2.-.

81 86 146 155

2BH7410-0..1.-.

90 101 162 182

2BH7510-0..1.-.

93 111 167 200

2BH7510-0..2.-.

120 112 216 202

2BH7610-0..1.-.

118 124 212 223

2BH7610-0..3.-.

118 124 212 223

Two-impeller design

Model

Temperature increase

∆T [K]

approx.

[F]

approx.

50 Hz 60 Hz 50 Hz 60 Hz

2BH7220-0..2.-.

55 77 99 139

2BH7220-0..5.-.

74 110 133 198

2BH7320-0..5.-.

81 124 146 223

2BH7420-0..2.-.

89 80 160 144

2BH7420-0..5.-.

121 117 218 211

2BH7520-0..2.-.

89 102 160 184

2BH7520-0..7.-.

125 110 225 198

2BH7620-0..3.-.

124 126 223 227

2BH7620-0..5.-.

124 128 223 230

Three-impeller design

Model

Temperature increase

∆T [K]

approx.

[F]

approx.

50 Hz 60 Hz 50 Hz 60 Hz

2BH7530-0..8.-.

120 120 216 216

2BH7630-0..6.-.

120 120 216 216


Advertising