Description
Connections
2
2
Fig. 1 Casing open 
(with PCB) 
Fig. 2 Casing without PCB
1 PCB holder 
2 Wall fixing 
3 Cable hole 
Note: 
The switch position described applies when the cover is open. 
Ground for LED (yellow)
Switch S2
12V for LED
NO 
COM 
NC 
NO 
COM 
NC 
S2
S1
NO 
COM 
NC 
NC 
NO 
COM 
Tamper
contacts
Switch S1
12V for LED 
 
Ground for LED (red
)
1 2
2
3
1
                                    Advertising
                    
                        
                    
                            
                            