3. Insert the key in the cylinder and turn it clockwise to its end

stop so that the red LED lights up. Keep the key in this
position.

4. After about 3 seconds, the red and green LED flash

alternately and the transmitter sends the learn message.

5. Check that the alarm system has recognised the detector.

6. Program

no supervision for this detector.

7. Program the zone as “Latch KSW” zone type. If you

program the zone as “BlLatch KSW delay”, the system
starts the exit delay time following activation.

8. Switch the alarm centre back to normal operating mode.



Technical data

Dimensions (surface fitting)

85 x 114 x 42mm (WxHxD)

Protection type

IP55

Weight

450g

Frequency

868.65 MHz

HF immunity

20V/m 80MHz–1GHz

Modulation

AM

Supervision

None

Battery

9V block

Battery lifetime

Ca. 1 year

Ambient operating temperature

-10°C – 50°C


The manufacturer reserves the right to make technical modifications
without prior notice.