5. Description of the DIP switches and status LEDs

5.1 DIP switches












Number

Function

ON position

OFF position

1

Master (CPE) / Slave (CO)

Control unit (Master)

End device (Slave)

2

Transmission

Fast mode

Interleave mode

3 Transmission

rate

Unlimited

Limited

4

Signal-to-noise-ratio

6 dB

9 dB


DIP 1: Master / Slave

ON position

Control device

Use this switch position to connect the device to a PC or a
router which accesses the network camera on the slave side.

OFF position

End device

Select this switch position to use the device on the network
camera.

DIP 2: Transmission

ON position

Fast mode

Use this setting to establish a fast data connection. Please
observe that data loss could occur using this setting.

OFF position

Interleave mode

Use this setting if there is a high data rate, and thereby avoid
any data loss on the transmission range.

DIP 3: Transmission rate

ON position

Unlimited

Use this setting to utilise a maximum data connection with a
transmission rate of up to 100 MB/s download/60 MB/s upload.

OFF position

Limited

Use this setting in the event that data losses occur on the
transmission line. The transmission rate is then decreased to
50 MB/s download / 30 MB/s upload in order to reduce the
data loss.


DIP 4: Signal-to-noise-ratio (SNR)

ON position

6 dB

Standard noise reduction which is used to compensate
interference on the line.

OFF position

9 dB

Increased noise reduction; the signal-to-noise ratio is
increased in this mode. This will be necessary in the event that
increased data loss occurs on the wiring section. The
maximum transmission path is then reduced in this mode.