ABUS TVHD51000 User Manual

Page 33

Advertising
background image

33

COMMUNICATION


COMMUNICATION
CAMERA ID

1

BAUD RATE

2400

RETURN


Function

Description

CAMERA ID

1~255
Setting for the RS-485 camera ID (ID 0 is reserved for the control
unit)

BAUD RATE

2.400 / 4.800 / 9.600 / 115.200
Setting for the baud rate of the RS-485 communication interface.

RETURN

Back to main menu



ALARM DETECT

When this function is activated, the camera sets a required zoom factor with activated switching
input. Once the set time has elapsed, the starting position is reset automatically. (The zoom factor is
not retained or will not be used again for further active switching input. The switching input must be
deactivated.)


ALARM DETECT
ALARM IN

ON

ZOOM RATIO

14X

DELAY TIME

10 SEC


DEFAULT

OFF

RETURN

Function

Description

ALARM IN

ON: Zoom factor is activated with active switching input
OFF: Zoom factor is deactivated with active switching input

ZOOM RATIO

Setting for the zoom factor for active switching input

DELAY TIME

Delay time in which the zoom factor remains set

DEFAULT

“ON” resets the settings on this page

RETURN

Back to main menu