Accent light, Electrical and photometry guide (1-light), Contact factory – Alera Lighting AL 1 Light - Electrical and Photometry Guide User Manual

Page 3: Contact factory contact factory, Photometry

Advertising
background image

Electrical and Photometry Guide (1-Light)

ACCENT LIGHT

Page 3/3 Rev. 01/14/14

© 2014 Alera Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

10

9
8
7
6
5
4
3
2
1
0

0 1 2 3 4 5 6 7 8 9 1 0
Distance from Wall

-2.5

0

24 29 29 26 22 18 14 11 9 7

17 20 21 21 19 17 15 13 11 9

42
16

9
6
4
3
3
3
2

10

9
8
7
6
5
4
3
2
1
0

0 1 2 3 4 5 6 7 8 9 1 0

-2.5

0

22 26 27 25 21 17 14 11 9 7

10

9
8
7
6
5
4
3
2
1
0

0 1 2 3 4 5 6 7 8 9 1 0

-2.5

0

Contact

Factory

10

9
8
7
6
5
4
3
2
1
0

0 1 2 3 4 5 6 7 8 9 1 0

-2.5

0

Contact

Factory

10

9
8
7
6
5
4
3
2
1
0

10

9
8
7
6
5
4
3
2
1
0

10

9
8
7
6
5
4
3
2
1
0

0 1 2 3 4 5 6 7 8 9 1 0
Distance from Wall

0 1 2 3 4 5 6 7 8 9 1 0

0 1 2 3 4 5 6 7 8 9 1 0

-2.5

0

-2.5

0

-2.5

0

29 32 31 27 22 17 12 9 7 6

20 22 23 22 20 17 14 12 9 7

48
19
11

7
5
4
4
3
3

Contact

Factory

Contact

Factory

10

9
8
7
6
5
4
3
2
1
0

10

9
8
7
6
5
4
3
2
1
0

0 1 2 3 4 5 6 7 8 9 1 0
Distance from Wall

0 1 2 3 4 5 6 7 8 9 1 0

-2.5

0

-2.5

0

34 39 39 35 30 25 20 16 13 10

23 27 28 27 25 22 20 17 14 12

90
38
21

14
11

9
7
7
5

30 37 37 34 30 25 21 17 13 10

20 24 26 26 24 22 20 17 15 12

88
33

18
12

9
8
7
6
5

Negative

Static

Pressure

-

Inches

of

Water

Return/Extract Air Flow Rate-CFM

0 15 20 40 60 80 100 200 400 600 800 1000

.10

.08

.06

.04

.02
.015

10

9
8
7
6
5
4
3
2
1
0

10

9
8
7
6
5
4
3
2
1
0

0 1 2 3 4 5 6 7 8 9 1 0
Distance from Wall

0 1 2 3 4 5 6 7 8 9 1 0

-2.5

0

-2.5

0

28 32 32 29 25 21 17 13 10 8

19 22 23 23 21 19 17 14 12 10

35
15

9
6
5
4
3
3
2

25 29 30 28 25 21 17 14 11 8

17 20 21 21 20 19 17 14 12 10

37
14

8
5
4
3
3
3
2

RECESSED / AL EPG 1

PHOTOMETRY

Illumination levels shown may be used as a quick guide. For tests on specific room sizes or other shielding material contact your Alera Lighting representative.

Note: For total flow multiply air flow rate by number of 4' sections.

WITH TOP REFLECTOR

FLUSH, WITH REFLECTOR

FLUSH

WITH REFLECTOR

NO REFLECTOR

FLUSH

1" REGRESS

NO REFLECTOR

1" REGRESS

1" REGRESS, WITH REFLECTOR

4" REGRESS

EXTRACT AIR DATA

Footcandle plots at left and below reflect the following test conditions:

1. Room size 30' Ч 30' Ч 10'.
2. Readings shown are centered on a 20' row.
3. Reflectance 80-50-20.
4. Lamp Lumens 3200.
5. Horizontal printed in italic at floor level and at 2.5'.
6. Vertical fc at wall are printed in italic.
7. All readings are initial footcandles with ballast factor of .95 included.

Advertising