Alpha Technologies CE3G User Manual
Page 14

14
745-738-C0-001 Rev. A
1.2 Installation, continued
1.2.3 Gas Box Modifi cation
1. To make room for drilling, loosen fl are fi tting and rotate LFPS to the right.
Pivot assembly
Loosen fi tting
2. Pull the black and white LFPS wires through to the gas utility box enclosure. Take
care not to damage the connector contacts.
3. Loosen the existing bulkhead fi tting and remove.
4. Use #4 UNIBIT to enlarge and deburr the LFPS wire hole to 7/8".
Fig. 1-6, LFPS Assembly
Fig. 1-7, LFPS Wiring, Bulkhead Fitting
Fig. 1-8, Outside Bottom View, Gas Utility Box
3/4"
3.00"
+
Existing opening
for braided hose
7/8" dia. opening
for Strain Relief
Connector
5. Drill and deburr 7/8" dia. opening in bottom of gas box as indicated in Fig. 1-8.
6. Clean metal shavings from gas box and install strain relief connector.
Enlarge to 7/8" dia.