NOTES ON RECOVERY OF DEEPLY DISCHARGED BATTERIES:
a.

Not all deeply discharged batteries can be recovered.

b.

Most weak batteries will be detected while charging. However, some batteries which have been recovered from a deep discharge will
maintain an acceptable open circuit voltage but have a reduced capacity under load. Always load test or otherwise test a recovered battery
to determine if the CCA capacity is within 80% of the rated value.

c.

Some large deeply discharged batteries may be recovered, but are not recharged enough in the 70 minute maximum charge time to be put
back into service. Either put it on a suitable finish charger, such as AEC Model 9410 or 9420, or allow battery to cool and charge again on
this charger.

WIRING DIAGRAM

M

ODEL

6003 REPAIR PARTS

Item

Description

Part No.

1 Front

Leg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 605183

2

Axle w/nuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610052

3

Wheel w/nuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610849

4

Rectifier w/wiring harness . . . . . . . . . . . . . . . . . . . . 610948

5

Transformer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610949

6

Fan Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610189

7

Fan Motor w/blade . . . . . . . . . . . . . . . . . . . . . . . . . . 610190

8

AC Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . 610920

9

DC Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . 610536

10

Switch (Flooded/Seal or On/Off), qty. 1 . . . . . . . . . . 610918

11

Switch (Manual Start), qty. 1 . . . . . . . . . . . . . . . . . . 610954

12

AC Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610951

13

Side Terminal Adapter (qty. 1) . . . . . . . . . . . . . . . . . 610181

14

DC Cable Positive . . . . . . . . . . . . . . . . . . . . . . . . . . 610952

15

DC Cable Negative . . . . . . . . . . . . . . . . . . . . . . . . . 610953

16

Clamps (1 pair w/jaws) . . . . . . . . . . . . . . . . . . . . . . . . . 6202

17

Jaw Kit (repairs 1 clamp) . . . . . . . . . . . . . . . . . . . . . . . 6204

18

PCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610950

MAINTENANCE INSTRUCTIONS

Worn clamps should be replaced. Worn parts can lead to poor connections and present a safety hazard. See parts list for part number of D.C.
Cord kit. Any Maintenance or repair of this unit that involves disassembly of the cabinet should be done only by a qualified serviceman.
Incorrect reassembly may result in a risk of electric shock when the unit is subsequently used.