Length of charge, Assembly instructions, Operating instructions – Associated Equipment 6006 User Manual

Page 3: Caution

Advertising
background image

20.

NOTE: SIDE TERMINAL TO BE USED IN POSITIVE CLAMP ONLY!

For instructions for NEGATIVE clamp attachment refer to

section 17e or 17f.

3

Storage position
Will not get lost. Always ready to use.

Extended position

Thrust on terminal

Note: Pressure, when handle is squeezed,
holds adapter firm. Will not slip back.

Note: Clamp is released and spring
tension holds adapter firm.

21.

LENGTH OF CHARGE

a.

Test the battery for state of charge. Do not charge if it is over 75% charged or the battery is determined to be defective.

b.

Set beginning amps charge rate for size of battery and state of charge per charts

c.

Charge for length of time per charge,

d.

Discontinue charge when the specific gravity of electrolyte reaches 1.260 or above. A temperature compensating hydrometer should be used
for this reading. Discontinue charge if the battery begins to gas excessively or if the temperature of the electrolyte reaches approximately
125

°F. Do not overcharge batteries. Overcharging results in excessive water loss and eventual damage to the battery.

23.6

11.8

5.9

1.110

23.8

11.9

5.95

1.140

24.2

12.1

6.05

1.185

24.8

12.4

6.2

1.225

25%

50%

75%

DEAD

Open Circuit Voltage-24 V.

Open Circuit Voltage-12 V.

Open Circuit Voltage-6 V.

Specific Gravity

STATE OF CHARGE

STATE OF CHARGE TABLE

Cold Cranking Amps

Reserve Capacity

Ampere Hours

BATTERY SIZE

60

90

350

80+

100+

400+

40

60

275

BATTERY SIZE TABLE

LARGE

MEDIUM

SMALL

BATTERY SIZE %CHARGE

0-25

30

30

30

45

45

50

20

20

20

30

35

40

5

5

20

25

15

25

20

35

55

15

25

45

10

20

30

20

40

55

15

30

50

10

20

30

30

60

90

25

45

70

15

30

45

15

15 15 15

10

10

10 10 10

15 30 45 60 75 90

A

M

P
E
R
E
S

SMALL

MEDIUM

LARGE

CHARGE RATE Vs. MINUTES CHARGE

25-50

50-75

50-75

25-50

0-25

50-75

25-50

0-25

MINUTES

ASSEMBLY INSTRUCTIONS

Attach the handle to the charger using the four screws provided.

OPERATING INSTRUCTIONS

CAUTION

- This battery charger must be fully assembled before operating. Failure to do so may result in risk of injury.

USE OF INSTRUMENT PANEL:
The CHARGE TIME timer has an OFF position, a CONTINUOUS CHARGE position and a timed charge range from 0 to
120 minutes.
a. OFF - Always make sure the timer is in the OFF position before connecting or disconnecting the clamps from the
battery. The charger will not charge with the timer in this position.
b. CONTINUOUS CHARGE - This position is used for slow charging or parallel charging and will not turn the charger off.
Do not use this position for fast charging.
c. 0 to 120 MINUTES TIMED CHARGE - The timer will automatically turn the charger off at the end of the pre-set
charging time. Turn the timer past 20 before setting the desired time.

TO CHARGE BATTERIES

Make connections to the battery per the instructions in previous sections of this manual.
Determine if the battery is 6, 12 or 24 volts and then set the CHARGE VOLTAGE switch to 6V for a 6 volt battery, 12LO for a 12 volt battery or 24V for a
24 volt battery.
Turn the timer on and read the AMPERES meter.
If a higher rate of charge is desired for charging 12 volt batteries, set the CHARGE VOLTAGE switch to the 12HI position.
Set the timer to the desired minutes charge.
DO NOT USE THE 12V START POSITION TO CHARGE BATTERIES.

Advertising