Pipe detail, Sidewall detail, Atas international, inc – ATAS Granutile Panel User Manual

Page 4

Advertising
background image

Pipe Detail

Step 1

Cut on the proper pipe

diameter marked on the

flashing.

Step 2

Position over pipe and slide

down the pipe.

Step 3

Apply polyurethane sealant

to the bottom of the base.

Step 4

Mold the flexible base

to the panel contours.

Step 5

Fasten with 1/4” x

1-1/8” drilling

fastener every 1-

1/2” around the

base.

Pipe drawings provided by Triangle Fasteners

Tools and Rules:

Basic Equipment Required:
Tie-off ropes, safety harness, long level, ladders, scaffolding with
approved planking, extension cords with approved ground plugs
and services.
Additional Tools:
Metal folding tool, hammer, chalk line, measuring tape, metal cut-
ting tools - nibblers, drills, hacksaw, utility knife, pop-rivet gun,
caulking guns, layout and combination square, C clamps, sheet
metal shears (including RH, LH, straight and overhand). Power
driven screw gun with proper bits, depth setting nosepiece, vari-
able speed.
Choose the correct equipment and tools to do the job in a
safe manner. Wear safety gear and follow OHSA require-
ments.

Follow of few simple rules:

1. Never cut the panels with an abrasive cut-off wheel or torch, as
this will damage the finish.
2. Do not weld the trim or panels.
3. Remove any small burrs left by cutting, screwing or drilling.
4. Remove protective masking immediately after trim is installed.
5. Caution should be taken when unloading the panels to prevent
damage.
6. Use appropriate screws for the type of underlayment and long
enough to fully penetrate and secure the panel.
7. The stored materials should be kept dry.
8. Do not cut on finished roof. Remove all drill spirals, chips and
dust immediately.
9. Seal neoprene closures and soft cell foam by applying appropri-
ate sealant to both surfaces.
10. Put appropriate sealant/butyle tape between overlapping trims.
11. Overlap trims in a manner not to impede the flow of water.

For further information or assistance, contact our Residential Product Support at 877-286-3320

©2006 Accel Roofing Products. All
rights reserved. Granutile Panel is a
tradename owned by ATAS
International, Inc.

ATAS International, Inc.

Corporate Office
6612 Snowdrift Road
Allentown, PA 18106

Sidewall Detail

1. Install ATA-Shield** along roof plane and up side-
wall.

2. Lay panel in place as shown and bend the edge
of the panel up against the wall to create a water
diverter. Fasten the bend edge of the panel into the
wall.

3. Face fasten top of Zee Bar flush to the wall. Be
sure the lower portion of the Zee Bar covers the
panel fastener in the wall.

4. Place sealant at the top of the Zee Bar as shown..

Note Regarding Trim Details
The applicaiton of flashing and trim requires a detailed approach. Consideration should be given to the roof’s geometry and course it
creates for water run-off. Proper planning regarding the sequence of material overlap is critical. Sealants, such as butyl tapes and
tripolymers, should be used at overlapping trim edges, in conjunction with exposed fasteners, and to seal flashings and other ancillar-
ies. All fasteners should be properly tightened and not overdriven at an angle. Fasteners that are too loose can “back out” over time.
An overdriven fastener may cause a depression in the material, which becomes a collection point for standing water.

Appropriate Sealant

SWR9XX Wood Screw 2”

HGA412 Z Bar

HGT144
Granutile Panel

#12 x 1”
Wafer Head
Screws

LAT240

Advertising