Eave detail gable detail valley detail – ATAS Dutch Seam User Manual

Page 2

Advertising
background image

Eave Detail

Gable Detail

Valley Detail

1. In re-roofing applications: cut back and remove

existing shingles and drip edge to be flush with
the eave and gable lines, or as required
to install underlayment.

2. In all applications: apply ATA-Shield** along eave

and up the roof to a point at least 24” beyond
outside face of exterior wall.

3. Install drip edge against fascia trim. Lay

ATA-Guard* over eave trim.

4. Trim (cut) seam and water leg back to allow for

turn down. Install panel by sliding lower flanged
edge over drip edge.

5. Optional end closure is to pop-rivet cap in

place as shown in sketch.

General Note: Before any installation be sure to lay

ATA-Shield** in all areas where ice & water can
occur. ATA-Guard or appropriate underlayment
should be installed over the entire roof. When
asphalt based felt underlayment is used install a slip
sheet, such as rosin paper, to minimize friction.

1. At gable start detail, install gable trim starter cleat

with appropriate fasteners at 2’-0” into
fascia board.

2. At end gable, cut panel to appropriate width to

allow room for clips at gable end. If panel cut off is
3” or wider install cut off portion of panel
underneath last panel w/ butyl tape applied in
between the two panels and install clips before
installing gable assembly.

3. Apply double-faced butyl sealant as circled in

sketch. Fasten “Z” closure to panel with pop-rivets.

4. Install starter cleat at end detail same as start detail.
5. At both ends snap gable/rake trim over starter cleat

and “Z” closure to lock into place. Pop-rivet these
two pieces together with one pop-rivet per
trim length.

1. Install ATA-Shield** approximately 18” up

both sides of the valley line.

2. Lay valley pan in valley center. Locate joggle

cleat at 4” to 6” from valley center.

3. Install joggle cleat. Fasten 6” o.c. through

butyl tape and pan into substrate.

4. Turn under edge of panel to slide into joggle cleat.

Fasten with clips at 2’-0” o.c.

Underlayments: ATA-Shield** is the recommended self adhesive underlay-
ment for eaves, sidewall and any critical areas exposed to ice damming
and extensive water run off.
Available in 65’-8” x 39-3/8” rolls (200 sq. ft. per roll).

Underlayments: ATA-Guard* is a polyolefin based, 100%
asphalt free, high strength reinforced roofing
underlayment for use beneath metal roofing on steep
slope applications. 1000 sq. ft. per roll at 48” wide.

MDA800 Valley Pan

#12 x1”
Wafer Head
Screws

Dutch Seam Panel

Anchor Clips

Allow f

or T

her

mal Mo

vement

6” Max.

Butyl Tape Sealant

MDA975 Joggle Cleat

4” Min. to 6” M

ax.

MDA910 “Z” Closure

#12 x1” Wafer Head Screws

Dutch Seam Panel

Anchor Clips

Painted Pop-Rivet

MDA210 Gable/Rake Trim

MDA211 Gable/Rake
Starter Cleat

Panel Overlap
w/ double sealant
& pop-rivet

Start Gable Detail

End Gable Detail

MDA11X
Drip Edge

#12 x1” Wafer Head Screws

Dutch Seam Panel

Anchor Clips

End Closure

Allow f

or Ther

mal Movement

6” Max.

ATA-Guard*

ATA-Shield**

Advertising