Atec Agilent-346a User Manual
Page 22

22
Designing and Probing with Target Connections
For All Agilent Logic Analyzers with 40-pin Pod Connectors
E5404/06A 34-Channel
Single-Ended Probe
Logic Analyzer
Signal Name
Pad #
Channel
Pod
D0
A1
➞
0
Whichever pod
D1
A2
➞
1
is connected to
Ground
A3
“Odd” on the
D4
A4
➞
4
E5404/06A
D5
A5
➞
5
probe
Ground
A6
Clock 1+
A7
➞
Clock
GND/NC/Clock 1– A8
Ground
A9
D10
A10
➞
10
D11
A11
➞
11
Ground
A12
D14
A13
➞
14
D15
A14
➞
15
Ground
A15
Whichever pod
D2
A16
➞
2
is connected to
D3
A17
➞
3
“Even” on the
Ground
A18
E5404/06A
D6
A19
➞
6
probe
D7
A20
➞
7
Ground
A21
D8
A22
➞
8
D9
A23
➞
9
Ground
A24
D12
A25
➞
12
D13
A26
➞
13
Ground
A27
E5404/06A 34-Channel
Single-Ended Probe
Logic Analyzer
Signal Name
Pad #
Channel
Pod
Ground
B1
Whichever pod
D2
B2
➞
2
is connected to
D3
B3
➞
3
“Odd” on the
Ground
B4
E5404/06A
D6
B5
➞
6
probe
D7
B6
➞
7
Ground
B7
D8
B8
➞
8
D9
B9
➞
9
Ground
B10
D12
B11
➞
12
D13
B12
➞
13
Ground
B13
D0
B14
➞
0
Whichever pod
D1
B15
➞
1
is connected to
Ground
B16
“Even” on the
D4
B17
➞
4
E5404/06A
D5
B18
➞
5
probe
Ground
B19
GND/NC/Clock 2– B20
Clock 2+
B21
➞
Clock
Ground
B22
D10
B23
➞
10
D11
B24
➞
11
Ground
B25
D14
B26
➞
14
D15
B27
➞
15