Atec Agilent-4286A User Manual
Page 12

12
Typical Measurement Accuracy
Conditions of typical accuracy specifications
•
Open/Short/50
Ω
calibration must be done. Calibration ON.
•
Averaging (on point) factor is larger than 32 at which calibration is done if Cal points is set to USER
DEF.
•
Measurement points are same as the calibration points.
•
Environment temperature is within
±
5
°
C of temperature at which calibration is done, and within 13
°
C to
33
°
C. Beyond this environmental temperature condition, accuracy is twice as bad as specified.
•
7 mm connector is used.
|Z|, |Y| Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±(E
a
+ E
b
) [%]
θ
Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± [rad]
L, C, X, B Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±(E
a
+ E
b
)
×
[%]
R, G Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±(E
a
+ E
b
)
×
[%]
D Accuracy (
∆∆∆∆∆
D)
@ |D
N
tan | < 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±
Especially, @ D
x
≤
0.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±
Q Accuracy (
∆∆∆∆∆
Q)
@ |Q
N
tan | < 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±
Especially, @
≥
Q
x
≥
10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±Q
N
2
Where,
E
a
: depends on measurement frequency as follows:
1 MHz
≤
Frequency
≤
100 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.56 + 0.03 [%](Typical)
100 MHz<Frequency
≤
500 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.63 + 0.03 [%](Typical)
500 MHz<Frequency
≤
1000 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.70 + 0.03 [%](Typical)
E
b
: (Z
s
/|Z
x
| + Y
0
|Z
x
|)
ЧЧЧЧЧ
100 [%]
V
osc
: OSC level [V]
Z
x
: impedance measurement value [
Ω
]
Z
s
and Y
o
depend on number of point averaging (N
av
) and OSC level (V
osc
) as follows:
(E
=
+ E
>
)
100
(1 + D
N
)
√
(E
=
+ E
>
)
100
(E
=
+ E
>
)
100
(E
=
+ E
>
)
100
E
=
+ E
>
100
(1 + Q
N
2
)tan( )
E
=
+ E
>
100
1
µ
Q
N
tan( )
10
(E
=
+ E
>
)
(E
=
+ E
>
)
100
0.03
8
OSC
0.03
8
OSC
0.03
8
OSC
Measurement Conditions
Z
s
[m
Ω
Ω
Ω
Ω
Ω
]
Y
o
[
µµµµµ
S]
Number of Point
OSC Signal Level
(Typical)
(Typical)
Averaging (N
av
)
(V
osc
)
0.2 V
≤
V
osc
≤
1 V
20 + 0.05
×
f
[MHz]
7 + 0.1
×
f
[MHz]
0.01 V
≤
V
osc
< 0.2 V
Ч
(20 + 0.05
Ч
f
[MHz]
)
Ч
(7 + 0.1
Ч
f
[MHz]
)
0.2 V
≤
V
osc
≤
1 V
7 + 0.05
×
f
[MHz]
5 + 0.1
×
f
[MHz]
0.01 V
≤
V
osc
< 0.2 V
Ч
(7 + 0.05
Ч
f
[MHz]
)
Ч
(5 + 0.1
Ч
f
[MHz]
)
1
≤
N
av
≤
7
N
av
≥
8
0.2
8
OSC
0.2
8
OSC
0.2
8
OSC
0.2
8
OSC
(1 + D
N
2
)tan( )
1
µ
D
N
tan( )
E
=
+ E
>
100
E
=
+ E
>
100
(1 + Q
N
)
√