A wide range of accessories support the Agilent
8720 family of network analyzers, including cali-
bration kits, verification kits, cables and adapters
in both 7 mm, 3.5 mm, Type-N, and 2.4 mm coax
and in the standard waveguide bands. The stan-
dards used in the 3.5 mm, Type-N, and 2.4 mm cal-
ibration and verification kits use precision slotless
connectors (PSC-3.5, PSC-N, and PSC-2.4).

Calibration kits

Vector accuracy enhancement procedures require
that the systematic errors of the measurement sys-
tem be characterized by measuring known devices
(standards) on the system over the frequency
range of interest. Agilent Technologies offers the
following types of calibration kits:

Standard calibration kits
Contain open circuits, short circuits, and both
fixed and sliding terminations in both sexes for all
connector types (except 7 mm, a sexless connec-
tor). Connector gauges are included in these kits
for maintaining each standard’s connector inter-
face. Standard calibration kits that include RTL
adapters and devices are also available in 7 mm
and 3.5 mm connectors.

Precision calibration kits
Have precision 50

Ω

airline(s) for performing the

Thru-Reflect-Line (TRL) calibration. These kits also
contain the open circuit, short circuit, and fixed
terminations used for traditional open-short-load
calibration techniques.

Accessories

Calibration kits

Frequency

Return

ResiduaI

ResiduaI

Cal Kit Type

Range (GHz)

Connector

Return Loss,

Return Loss,

Loss, Airline

Directivity

2

Source Match

2

and Name

f

min

–f

max

Type

Fixed Load

Sliding Load

at f

max

at f

max

at f

max

Precision
85052C

0.045 to 26.5

3.5 mm

≥

46 dB, DC to 2 GHz

—

50 dB

50 dB

50 dB

Standard
85050B

0.045 to 18

7 mm

≥

52 dB, DC to 2 GHz

≥

52 dB, 2 to 18 GHz

—

45 dB

30 dB

85052B

0.045 to 26.5

3.5 mm

≥

44 dB, DC to 3 GHz

≥

44 dB, 3 to 26.5 GHz

—

44 dB

30 dB

85054B

0.045 to 18

Type-N

≥

48 dB, DC to 2 GHz

≥

42 dB, 2 to 18 GHz

—

42 dB

30 dB

85056A

0.045 to 50

2.4 mm

≥

42 dB, DC to 4 GHz

≥

36 dB at 50 GHz

—

38 dB

31 dB

Economy
85050D

0.045 to 18

7 mm

≥

38 dB, DC to 18 GHz

—

—

36 dB

30 dB

85052D

0.045 to 26.5

3.5 mm

≥

30 dB at 26.5 GHz

—

—

36 dB

29 dB

85054D

0.045 to 18

Type-N

≥

34 dB at 18 GHz

—

—

34 dB

28 dB

85056D

0.045 to 50

2.4 mm

≥

26 dB at 50 GHz

—

—

26 dB

23 dB

85056K

0.045 to 40

2.92 mm

≥

26 dB at 40 GHz

—

—

25 dB

22 dB

Waveguide
X11644A

1

8.2 to 12.4

WR-90

≥

42 dB,8.2 to 12.4 GHz

50 dB

40 dB

30 dB

P11644A

1

12.4 to 18

WR-62

≥

42 dB,12.4 to 18 GHz

50 dB

40 dB

30 dB

K11644A

1

18 to 26.5

WR-42

≥

42 dB,18 to 26.5 GHz

50 dB

40 dB

30 dB

R11644A

26.5 to 40

WR-28

—

46 dB

50 dB

40 dB

30 dB

Electronic
85060A

3

1 to 18

7 mm

—

—

—

44.5 dB

39.5 dB

Option 001

0.45 to 2

7 mm

—

—

—

51 dB

44.5 dB

85062A

3

1 to 26.5

3.5 mm

—

—

—

41.5 dB

35.5 dB

Option 001

0.45 to 2

3.5 mm

—

—

—

50.5 dB

43.5 dB

85064A

3

1 to 18

Type-N

—

—

—

44.5 dB

39.5 dB

Option 001

0.45 to 2

Type-N

—

—

—

50 dB

43.5 dB

1. Airline return loss, directivity, and source match are typical values for these calibration kits.
2. Residuals based on Agilent 8720D at fmax =20 GHz for 3.5 mm kits or on Agilent 8722D at fmax= 40 GHz for 2.4 mm kits.
3. Requires an Agilent 85060C control unit.

Advertising