Atec Agilent-N5173B User Manual
Page 9

9
Broadband noise
1
() = measured
100 MHz
(–143 dBc/Hz)
500 MHz
(–155 dBc/Hz )
1 GHz
(–163 dBc/Hz )
10 GHz
(–150 dBc/Hz)
20 GHz
(–143 dBc/Hz)
40 GHz
(–135 dBc/Hz)
Residual FM (CW mode, rms) See frequency band table for N value
0.3 to 3 kHz bandwidth
< N* 0.5 Hz (meas)
0.05 to 15 kHz bandwidth
< N* 3 Hz (meas)
Residual AM (CW mode, +10 dBm, 0.3 kHz to 3 kHz bandwidth, rms)
< 2 GHz
< 0.01% (meas)
Harmonics [CW mode]
2
() = typical
Range
CW mode at +10 dBm
CW mode at +20 dBm
3
9 kHz to 200 MHz
< –48 dBc (–54)
< –38 dBc (–43)
> 200 MHz to 2 GHz
< –33 dBc (–40)
< –25 dBc (–31)
> 2 to 20 GHz
< –55 dBc (–65)
< –50 dBc (–55)
1. CW mode at +10 dBm for offsets > 10 MHz. In high signal to noise ratio mode (optimize S/N).
2. Specifications apply from +15 to +35 °C and are nominal for harmonics beyond specified frequency range.
3. Or maximum specified output power, whichever is lower.