Specifications 2236 – Atec Bruel-Kjaer-2236 User Manual

Page 3

Advertising
background image

3

STANDARDS:
Conforms with IEC 651 (1979) and 804 (1985)
Type 1, and ANSI S1.4 – 1983 and Draft S1.43,
6th September, 1992 Type 1

1

/

1

-octave filter set conforms with IEC 225 – 1966

and ANSI S1.11–86, order 3, Type 1–D (Types
2236 C and 2236 D only)
MEASURING RANGES:

NOISE FLOOR:
Typically:
18 dB(A)
Maximum: 20 dB(A) RMS
Includes preamplifier’s electrical noise and mi-
crophone’s thermal noise

DETECTORS:
Simultaneous RMS and Peak with independent
frequency weightings
Linearity Range: 80 dB
Pulse Range: 83 dB
Non-linear Distortion: Too small to affect ac-
curacy
Peak Detector Rise Time: <50

µ

s

FREQUENCY WEIGHTING:
Selected independently for RMS and Peak
RMS:
A, C according to IEC 651 Type 1
L: flat from 10 Hz to 20 kHz (

±

2 dB) with Type 1

tolerances
Peak:
C according to IEC 651 Type 1
L: flat from 10 Hz to 20 kHz (

±

2 dB) with Type 1

tolerances

FILTER (only available with Types 2236 C and
2236 D):
Band-pass Filters: Nine

1

/

1

-octave filters at

1

/

1

-octave intervals (base 10)

Centre Frequencies: 31.5, 63, 125, 250,
500 Hz, 1, 2, 4, 8 kHz
Maximum Noise Floor in Each Frequency
Band:

See diagram for details

* Only available with Types 2236 C and 2236 D when

filter selected.
Level non-linearity caused by noise floor is < 0.4 dB at
30 dB(A) (re IEC 651) and < 1 dB at 26 dB(A)

† Level non-linearity caused by noise floor is < 0.4 dB at

30 dB(A) (re IEC 651) and < 1 dB at 26 dB(A)

Range

(dB)

Max.

Peak

level

Upper limit (RMS) for

signals with crest

factor = 10 (20dB)

10

*

– 90

93

73

20

– 100

103

83

30 – 110

113

93

40 – 120

123

103

50 – 130

133

113

60 – 140

143

123

TIME WEIGHTING:

according to

IEC651

Type 1

DISPLAY:
4 line LCD showing:
• Measuring range and quasi-analogue bar

showing input signal

• Battery low, pause and overload with hold in-

dicators

• Time weighting and elapsed measurement

time

• Frequency weighting (Peak or RMS) or filter

centre frequency (only available with Types
2236 C and 2236 D), selected parameter with
level

Optional back-light
The quasi-analogue bar is updated 15 times per
second
Displayed parameter level updated once per sec-
ond

PARAMETERS:
Common (and UKi only):
MaxL, MinL, MaxP,
Peak, SPL, L

eq

, SEL, L

EP,d

and Overload in %

of measurement time
Specific:

Resolution:
L

N

Values: 0.5dB

Other Parameters: 0.1dB

EXCHANGE RATE:

RESET:
Resets Buffer (including elapsed time) to zero.
Warning prior to reset if elapsed time > 1 min.
Reset when changing frequency or time weight-
ing
Resets all results in Log, Memory and Buffer if
held down together with

Data

Optional reset when changing level of measure-
ment range (L

N

s not available if range change

is without reset)

MICROPHONE:
Type 4188 prepolarized free-field

1

/

2

condenser

microphone
Sensitivity: – 30 dB re 1 V/Pa

±

2 dB

Frequency Range: 8 Hz to 12.5kHz

±

2 dB

Capacitance: 12 pF

MEMORY:
40 Records of Overall Results
RESULT LOGGING:

Logged To: log or interface
Memory Capacity: 128 Kbytes (Types 2236 A
and 2236 C). Equivalent to 21600 sets of results
(for example, 6 hrs of 1s logging).
512Kbytes (Types 2236 B and 2236 D). Equiv-
alent to 86 400 sets of results (for example,
24 hrs of 1s logging)

SERIAL INTERFACE:
Compatible with EIA–574
Compatible with EIA– 232 – E with 25-pole adap-
tor
Baud Rate: 1200 – 19 200 (1200 – 9600 for
Japanese version)
Data Bits: 8
Stop Bit: 1
Parity: None
Handshake: Hardwire, XON/XOFF or None

Heading: Long or short (only short for USA
model)

DC OUTPUT:
Short-circuit protected coaxial LEMO socket (se-
ries 00)

* only L

eq

logged at this rate

Int.

USA

UKi

UKe

Jap.

S, F, I

S, F, I

S, F

S, F, I

S, F, I

Int.

USA

UKe

Jap.

L

Im

Inst.

IEL

LAE

LCE

LLE

L

AV,4

L

AV,5

Variable L

N

Defaults
(fixed for
Int. Version)

L

95

L

5

L

90

L

50

L

10

L

90

L

50

L

1

L

95

L

50

L

5

Int.

USA

UKi

UKe

Jap.

3

3, 4, 5

3

3

3, 5

Int.

USA

UKi

UKe

Jap.

L

eq

L

eq

L

eq

L

eq

L

eq

MaxL

L

10

MaxL

L

10

L

5

MaxP

L

90

MaxP

L

90

L

95

Log
Rate

Log
Cap.

Int.

USA

UKi

UKe

Jap.

0.1 s

*

36 m

1 s

6 h

10 s

2

1

/

2

d

30 s

7

1

/

2

d

1 m

15 d

5 m

75 d

10 m

150 d

15 m

225 d

30 m

450 d

60 m

900 d

Result
Output
Formats

Int.

USA

UKi

UKe

Jap.

Overall

Logged
(Printer)

Logged

(2318)

Logged
(Spreadsheet)

Level
Distribution

Cumulative
Disribution

Distribution
Resolution
(dB)

1 or 5

1 or 5 0.5, 1,

2, 5,

10

Specifications 2236

941683e

25

Noise/dB

Frequency Hz

31.563 125

8 k

C

A

LIN

20

15

10

Advertising