Atec EXFO-FTB-8120-8130NGE User Manual

Page 3

Advertising
background image

FTB-8120NGE/8130NGE Power Blazer

Optical Transport Network Testing

OTN as per ITU-T G.709 has recently introduced two new concepts: ODU0 and ODUflex. ODU0 is a new virtual container
of 1.25 Gbit/s bandwidth specifically defined for efficiently mapping Gigabit Ethernet services over OTN. As for ODUflex,
it is the most efficient sub-wavelength bandwidth management capability for transport line rates of 10 Gbit/s, 40 Gbit/s and
upcoming 100 Gbit/s. ODUflex allows providers to interconnect routers in ways that enable efficient bandwidth growth in steps
of 1.25 Gbit/s, eliminating the need to allocate a full fixed-rate ODU container to each connection, and allowing service providers
to transport efficiently and seamlessly across lower-cost optical infrastructures.

With OTN deployments rapidly increasing, so is the need for smaller, field-oriented OTN test equipment. The FTB-8120NGE/8130NGE
Power Blazer modules offer OTN test capabilities for verifying compliancy with ITU-T G.709 standards. The tests include:

›

OTU1 (2.7 Gbit/s) and OTU2

(10.7 Gbit/s) bit rates

›

ODU0 (1.25 Gbit/s) container with

Gigabit Ethernet and SONET/SDH
client signals mapping

›

ODUflex with Ethernet client signal

mapping

›

Overclocked OTU2 rates: OTU1e

(11.0491 Gbit/s), OTU2e (11.0957
Gbit/s), OTU1f (11.2701 Gbit/s) and
OTU2f (11.3176 Gbit/s)

›

Unframed optical signal testing at

10.7 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s, 11.2701 Gbit/s and
11.3176 Gbit/s rates

›

Synchronous mapping of SONET/SDH

signals within OTN as well as
synchronous and asynchronous
demapping

›

Forward error correction (FEC) testing

›

Service disruption time (SDT)

measurements

›

Multichannel SDT measurements and

real-time error/alarm monitoring for all
ODU0 channels

›

Round-trip delay (RTD) measurements

›

OTU, ODU, OPU overhead

manipulation and monitoring

›

OTU, ODU (including ODU TCM),

OPU layer alarms/errors generation
and analysis

›

OTU, ODU (including ODU TCM)

trace messages

›

Mux/demux of ODU1/ODU2 testing;

generation of four ODU1 into a single
ODU2 structure and transporting it
over a single wavelength

›

ODU multiplexing alarm-generation and

analysis

›

Through mode analysis

›

Intrusive Through mode

›

EoOTN testing using internally

generated 10 GigE LAN and mapping
onto OTU1e and OTU2e rates

›

10 GigE LAN mapping into OTU2

using GFP-F

G.709 DUT

OTUk Signal

Power Blazer modules support G.709
testing in either the FTB-200 or FTB-500.

Advertising