MLS-800

Microprocessor Controlled Ground Station Simulator

•

Test Operational Menu supports ICAO
1985 and EUROCAE ED-53A and
ED-36A

•

Complete Main Path Simulation:
Approach (AZ) and High Rate Azimuth
(HiAZ) Elevation (EL) Back Azimuth (BAZ)
Flare (FL)

•

Complete Multi-path (MP) Simulation
Capability:
Interference Pulses
Selectable Fade Rate Modulation of 0.05,
1 and 1000 Hz

•

Control of all Beam Parameters:
Angular Position Beam Amplitude
Referenced to the Preamble Norm and
Half Width Pulse Selectable Beam Width
at 0.5°, 1°, 2°, 3°, 4° or 5°

•

Sync Capability for: External Monitoring
Designating PFE and CMN Function
Designating Multi-path Function

•

Preamble Parity, Symmetry and Percent
Update

•

Simulates all Basic Data Words plus
Auxiliary Data Words with Parity Selection

•

Full Range of MLS Channels

Aeroflex is a leader in the design, manufacture

and marketing of Avionics test systems.

The MLS-800 is a microprocessor controlled Ground Station
Simulator designed to operate from a bench test environment. Test
parameters are selected via a 44-position keyboard and displayed on
test operational menus.

Other Features

• OCI Control for Right (RT), Left (LT) and Rear (RR)

• 75 dB AZ to EL Ratio Capability Propellor/Rotor Modulation at 1

to 100 Hz Variable in 1 Hz steps Morse Code Identification
Capability

• ARINC 429 Receiver with PFE and CMN calculations

• External RF Reference Input

• Clearance Pulse Simulation

• 6.75 Hz Modulation

• IEEE-488-1978 Interface for Remote Control Operation

S

SP

PE

EC

CIIF

FIIC

CA

AT

TIIO

ON

N

G

GE

EN

NE

ER

RA

AL

L R

RE

EQ

QU

UIIR

RE

EM

ME

EN

NT

TS

S

• Unless otherwise noted the following equipment performance char-

acteristics are warranted over the specified environmental conditions
following a 20 minute warm-up period.

• All RF measurements are referenced to 50 Ω.
• Accuracy and resolution stated in percent are referenced to measured

or desired values.

• Where resolution exceeds accuracy, resolution takes precedence.
• Notes are intended to provide information useful in applying the

instrument by giving specific setup information. Notes are found in
the notes section of this specification.